Comparison of mega-voltage cone-beam computed tomography prostate localization with online ultrasound and fiducial markers methods
Rent:
Rent this article for
USD
10.1118/1.2830381
/content/aapm/journal/medphys/35/2/10.1118/1.2830381
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/35/2/10.1118/1.2830381

Figures

Image of FIG. 1.
FIG. 1.

(a) An ultrasound image from a localization US dataset of a prostate patient; (b) a 2 MU-AP portal image of fiducial markers; (c) an axial MV-CBCT image of a prostate patient localized with CB, using at isocenter.

Image of FIG. 2.
FIG. 2.

Patient mean shift in all three directions for each localization device, along with the overall population mean shift (solid horizontal line) and standard deviation (dashed horizontal lines). One very large patient, whose skin markers were unreliable, was removed from the CBCT data set (open circle).

Image of FIG. 3.
FIG. 3.

Scatter plots of the localization data. (a) US AP view; (b) US SI view; (c) US LR view; (d) MV-CBCT AP view; (e) MV-CBCT SI view; (f) MV-CBCT LR view; (g) SM AP view; (h) SM SI view; (i) SM LR view.

Image of FIG. 4.
FIG. 4.

Histogram of the mean 3D shift values. (a) US data; (b) MV-CBCT data; (c) SM data.

Tables

Generic image for table
TABLE I.

Mean shift standard deviation in each dimension, for each localization system. The mean 3D shift and its standard deviation are also shown.

Generic image for table
TABLE II.

Percentage of shifts over in each dimension, for each localization system.

Generic image for table
TABLE III.

Summary of shifts in literature for US and SM.

Generic image for table
TABLE IV.

P values of the F test for equality of variance between the different pairs of data sets.

Generic image for table
TABLE V.

values of the Kolmogorov–Smirnov test that a pair of data sets are sampled from the same continuous distribution.

Generic image for table
TABLE VI.

Systematic error , random error and uniform CTV-to-PTV margin suggested by each data set.

Loading

Article metrics loading...

/content/aapm/journal/medphys/35/2/10.1118/1.2830381
2008-01-18
2014-04-24
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Comparison of mega-voltage cone-beam computed tomography prostate localization with online ultrasound and fiducial markers methods
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/35/2/10.1118/1.2830381
10.1118/1.2830381
SEARCH_EXPAND_ITEM