Comparison of fixed-beam IMRT, helical tomotherapy, and IMPT for selected cases
Rent:
Rent this article for
USD
10.1118/1.2890085
/content/aapm/journal/medphys/35/4/10.1118/1.2890085
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/35/4/10.1118/1.2890085

Figures

Image of FIG. 1.
FIG. 1.

Prostate case. Comparison of the dose distributions in the isocenter plane. (a) FFM IMRT, (b) sMLC IMRT, (c) HT, and (d) IMPT.

Image of FIG. 2.
FIG. 2.

Prostate case. DVHs comparison.

Image of FIG. 3.
FIG. 3.

Pediatric case. Comparison of the dose distributions in the isocenter plane. (a) FFM IMRT, (b) sMLC IMRT, (c) HT, and (d) IMPT.

Image of FIG. 4.
FIG. 4.

Pediatric case. Comparison of DVHs.

Image of FIG. 5.
FIG. 5.

Lung case. Comparison of the dose distributions in the isocenter plane. (a) FFM IMRT, (b) sMLC IMRT, (c) HT, and (d) IMPT.

Image of FIG. 6.
FIG. 6.

Lung case. DVHs comparison. *The target DVH when the maximum dose constraint was relaxed.

Image of FIG. 7.
FIG. 7.

Head-and-neck case A. Comparison of the dose distributions in the isocenter plane. (a) FFM IMRT, (b) sMLC IMRT, (c) HT, and (d) IMPT.

Image of FIG. 8.
FIG. 8.

Head-and-neck case A. DVHs comparison.

Image of FIG. 9.
FIG. 9.

Head-and-neck case B. Comparison of the dose distributions in the isocenter transversal plane. (a) FFM IMRT, (b) sMLC IMRT, (c) HT, (d) IMPT.

Image of FIG. 10.
FIG. 10.

Head-and-neck case B. Comparison of DVHs.

Tables

Generic image for table
TABLE I.

Prostate case. Prescriptions, cost function values, and dose statistics for each VOI.a

Generic image for table
TABLE II.

Pediatric case. Prescriptions, cost function values, and dose statistics for each VOI.

Generic image for table
TABLE III.

Lung case. Prescriptions, cost function values, and dose statistics for each VOI.a

Generic image for table
TABLE IV.

Head-and-neck case A. Prescriptions, cost function values, and dose statistics for each VOI. The EUD for a serial type cost function with equals the mean dose.

Generic image for table
TABLE V.

Head-and-neck case B. Prescriptions, cost function values, and dose statistics for each VOI.

Loading

Article metrics loading...

/content/aapm/journal/medphys/35/4/10.1118/1.2890085
2008-03-25
2014-04-18
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Comparison of fixed-beam IMRT, helical tomotherapy, and IMPT for selected cases
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/35/4/10.1118/1.2890085
10.1118/1.2890085
SEARCH_EXPAND_ITEM