2D-3D registration for prostate radiation therapy based on a statistical model of transmission images
Rent:
Rent this article for
USD
10.1118/1.3213531
/content/aapm/journal/medphys/36/10/10.1118/1.3213531
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/36/10/10.1118/1.3213531

Figures

Image of FIG. 1.
FIG. 1.

Presence of nonstationary noise in the kV projection radiographs. An ensemble of projection images was acquired on the benchtop imaging system. The noise in every image was computed by subtracting the mean of the 13 remaining images. The variance at every pixel for the 14 noise images was then plotted against the mean intensity value of the original 14 images. The variance and mean were strongly correlated as shown in (a), indicating the presence of nonstationary noise in the radiographs. The noise variance as a function of mean pixel intensity value in the filtered images is shown in (b).

Image of FIG. 2.
FIG. 2.

Registration results for the pose determination experiments with kV radiographs and kV CBCT data. A bar plot of the total error in registering the kV radiographs to the kV CBCT is shown in (a). The total registration error is shown for each of the three similarity measures, MLP, MLG, and ICC, for all 13 poses tested. All registration errors were less than . The performance of all three similarity measures was similar. A box plot of the absolute error in registering the kV radiographs to the kV CBCT for each of the six transformation parameters, and of the total registration error over all 13 poses tested is shown in (b). The horizontal lines show the lower quartile, median, and upper quartile values of the absolute registration errors for MLP, MLG, and ICC. The plus (+) sign indicates outlier values. Errors in estimating out-of-plane translations along the axis were the largest contributor to total registration error.

Image of FIG. 3.
FIG. 3.

Registration results for the pose determination experiments with MV portal images and kV CBCT data. A bar plot of the total error in registering the MV portal images to the kV CBCT is shown in (a). The total registration error is shown for each of the three similarity measures, MLP, MLG, and ICC, for all 15 poses tested. The registration errors were larger than with the kV data set. However, as with the kV dataset, the performance of all three similarity measures on the MV data was similar. A box plot of the absolute error in registering the MV portal images to the kV CBCT for each of the six transformation parameters, and of the total registration error for all 15 poses tested is shown in (b). The horizontal lines show the lower quartile, median, and upper quartile values of the absolute registration errors for MLP, MLG, and ICC. The plus (+) sign indicates outlier values. As with the kV dataset, errors in estimating out-of-plane translations along the axis were largest.

Tables

Generic image for table
TABLE I.

Displacements for the pose determination experiments conducted with the kV CBCT and kV radiographs.

Generic image for table
TABLE II.

Displacements for the pose determination experiments conducted with the kV CBCT and MV portal images.

Generic image for table
TABLE III.

Registration accuracy for the pose determination experiments with the kV CBCT and kV radiographs: Root mean square value of the error in estimating (1) each of the six transformation parameters, (2) the overall registration error , and (3) the registration error if errors in are ignored.

Generic image for table
TABLE IV.

Registration accuracy for the pose determination experiments with the kV CBCT and MV portal images: Root mean square value of the error in estimating (1) each of the six transformation parameters, (2) the overall registration error , and (3) the registration error if errors in are ignored.

Generic image for table
TABLE V.

Pose determination experiments with kV CBCT and kV radiographs: Mean and (standard deviation) of the absolute error in estimating each of the six transformation parameters, the overall registration error , and the registration error if errors in are ignored for the three similarity measures, MLP, MLG, and ICC.

Generic image for table
TABLE VI.

Pose determination experiments with kV CBCT and MV portal images: Mean and (standard deviation) of the absolute error in estimating each of the six transformation parameters, the overall registration error , and the registration error if errors in are ignored for the three similarity measures, MLP, MLG, and ICC.

Generic image for table
TABLE VII.

Estimated shifts in the patient’s setup relative to the treatment field obtained with the three similarity measures, MLP, MLG, and ICC. The patients planning CT was registered to weekly AP portal images acquired during treatment for weeks 1–8.

Loading

Article metrics loading...

/content/aapm/journal/medphys/36/10/10.1118/1.3213531
2009-09-11
2014-04-19
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: 2D-3D registration for prostate radiation therapy based on a statistical model of transmission images
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/36/10/10.1118/1.3213531
10.1118/1.3213531
SEARCH_EXPAND_ITEM