Calculation of electron and isotopes dose point kernels with fluka Monte Carlo code for dosimetry in nuclear medicine therapy
Rent:
Rent this article for
USD
10.1118/1.3586038
/content/aapm/journal/medphys/38/7/10.1118/1.3586038
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/38/7/10.1118/1.3586038

Figures

Image of FIG. 1.
FIG. 1.

Scaled DPK (F) for 10 kev (a) and 1 MeV (b) electrons in water and for 10 kev (c) and 1 MeV (d) electrons in bone. F values are reported as a function of the reduced radius (r/R CSDA).

Image of FIG. 2.
FIG. 2.

Comparison between fluka and  penelope v.2008 results vs other codes (etran, geant 4.8.2, and mcnpx v.2.5.0) for monoenergetic electrons: maximum percentage discrepancy between F values within 0.9·R CSDA(a), 0.8·R CSDA(b), and average discrepancy within 0.9·R CSDA(c).

Image of FIG. 3.
FIG. 3.

Scaled DPK (F) for 90Y (a) and 177 Lu (b) in water and for 90Y (c) and 177 Lu (d) in bone. F values are reported as a function of the reduced radius (r/X 90 ).

Tables

Generic image for table
TABLE I.

FLUKA vs  penelope v.2008 results in bone for monoenergetic electrons: maximum percentage discrepancy between F values within 0.8·R CSDA(Max_0.8), 0.9·R CSDA(Max_0.9), and average discrepancy within 0.9·R CSDA(Av_0.9).

Generic image for table
TABLE II.

Comparison between  penelope v.2008 and fluka results in water for beta emitting isotopes, considering the same beta spectrum (Ref. 25): maximum percentage discrepancy between F values within 0.8·X90 (Max_0.8), 0.9·X90 (Max_0.9), and average discrepancy within 0.9·X90 (Av_0.9).

Generic image for table
TABLE III.

Comparison between  penelope v.2008 and fluka results in bone for beta emitting isotopes, considering the same beta spectrum (Ref. 25): maximum percentage discrepancy between F values within 0.8·X90 (Max_0.8), 0.9·X90 (Max_0.9), and average discrepancy within 0.9·X90 (Av_0.9).

Generic image for table
TABLE IV.

Comparison between fluka soft tissue and water results for beta emitting isotopes, considering the same beta spectrum (Ref. 25): Maximum percentage discrepancy between F values within 0.8·X90 (Max_0.8), 0.9·X90 (Max_0.9), and average discrepancy within 0.9·X90 (Av_0.9).

Loading

Article metrics loading...

/content/aapm/journal/medphys/38/7/10.1118/1.3586038
2011-06-17
2014-04-24
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Calculation of electron and isotopes dose point kernels with fluka Monte Carlo code for dosimetry in nuclear medicine therapy
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/38/7/10.1118/1.3586038
10.1118/1.3586038
SEARCH_EXPAND_ITEM