1887
banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
oa
Increasing the oscillation frequency of strong magnetic fields above 101 kHz significantly raises peripheral nerve excitation thresholds
Rent:
Rent this article for
Access full text Article
/content/aapm/journal/medphys/39/5/10.1118/1.3702775
1.
1. J. P. Reilly, V. T. Freeman, and W. D. Larkin, “Sensory effects of transient electrical stimulation—Evaluation with a neuroelectric model,” IEEE Trans. Biomed. Eng. BME-32(12), 10011011 (1985).
http://dx.doi.org/10.1109/TBME.1985.325509
2.
2. D. R. McNeal, “Analysis of a model for excitation of myelinated nerve,” IEEE Trans. Biomed. Eng. BME-23, 329337 (1976).
http://dx.doi.org/10.1109/TBME.1976.324593
3.
3. J. P. Reilly and A. M. Diamant, “Spatially extended nonlinear node (SENN) model of electrostimulation of myelinated nerve,” available at http://www.artechhouse.com/static/reslib/reilly/reilly.html.
4.
4. J. P. Reilly, Applied Bioelectricity (Springer, New York, 1998).
5.
5. J. P. Reilly and A. M. Diamant, Electrostimulation (Artech House, Boston, 2011).
6.
6. J. P. Reilly, “Maximum pulsed electromagnetic field limits based on peripheral nerve stimulation: Application to IEEE/ANSI C95.1 electromagnetic field standards,” IEEE Trans. Biomed. Eng. 45(1), 137141 (1998).
http://dx.doi.org/10.1109/10.650371
7.
7. ICNIRP, “Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz),” Health Phys. 74, 494522 (1998).
8.
8. IEC 60601-2-33, Medical Electrical Equipment—Part 2–33: Particular Requirements for the Basic Safety and Essential Performance of Magnetic Resoance Equipment for Medical Diagnosis, 3rd ed. (IEC, Geneva, 2010).
9.
9. T. F. Budinger, H. Fischer, D. Hentschel, H. E. Reinfelder, and F. Schmitt, “Physiological effects of fast oscillating magnetic field gradients,” J. Comput. Assist. Tomogr. 15, 909914 (1991).
http://dx.doi.org/10.1097/00004728-199111000-00001
10.
10. D. J. Reinemann, L. E. Stetson, J. P. Reilly, N. K. Laughlin, S. McGuirk, and S. D. LeMire, “Dairy cow sensitivity and aversion to short duration transient currents,” ASAE Technical Paper No. 96-3087 (American Society of Agricultural Engineers, St. Joseph, MI, 1996).
11.
11. W. Irnich and F. Schmitt, “Magnetostimulation in MRI,” Magn. Reson. Med. 33, 619623 (1995).
http://dx.doi.org/10.1002/mrm.1910330506
12.
12. P. M. Glover, “Interaction of MRI field gradients with the human body,” Phys. Med. Biol. 54, R99R115 (2009).
http://dx.doi.org/10.1088/0031-9155/54/21/R01
13.
13. P. Mansfield and P. R. Harvey, “Limits to neural stimulation in echo-planar imaging,” Magn. Reson. Med. 29, 746758 (1993).
http://dx.doi.org/10.1002/mrm.1910290606
14.
14. B. Aksel, L. Marinelli, B. D. Collick, C. Von Morze, P. A. Bottomley, and C. J. Hardy, “Local planar gradient with order-of-magnitude strength and speed advantage,” Magn. Reson. Med. 58(1), 134143 (2007).
http://dx.doi.org/10.1002/mrm.21263
15.
15. C. Westbrook, C. K. Roth, and J. Talbot, MRI in Practice, 4th ed. (John Wiley & Sons, New York, 2011).
16.
16. D. J. Schaefer, J. D. Bourland, and J. A. Nyenhuis, “Review of patient safety in time-varying gradient fields,” J. Magn. Reson. Imaging 12, 2029 (2000).
http://dx.doi.org/10.1002/1522-2586(200007)12:1<20::AID-JMRI3>3.0.CO;2-Y
17.
17. K. F. King and D. J. Schaefer, “Spiral scan peripheral nerve stimulation,” J. Magn. Reson. Imaging 12, 164170 (2000).
http://dx.doi.org/10.1002/1522-2586(200007)12:1<164::AID-JMRI18>3.0.CO;2-R
18.
18. S. Nowak, “Nuclear magnetic resonance tomography apparatus having a resonant circuit for generating gradient fields,” U.S. patent 5,245,287 (14 September 1993).
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/39/5/10.1118/1.3702775
Loading
/content/aapm/journal/medphys/39/5/10.1118/1.3702775
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aapm/journal/medphys/39/5/10.1118/1.3702775
2012-04-18
2014-10-01

Abstract

Purpose:

A time-varying magnetic field can cause unpleasant peripheral nerve stimulation (PNS) when the maximum excursion of the magnetic field (ΔB) is above a frequency-dependent threshold level [P. Mansfield and P. R. Harvey, Magn. Reson. Med. 29, 746–758 (1993)]. Clinical and research magnetic resonance imaging(MRI) gradient systems have been designed to avoid such bioeffects by adhering to regulations and guidelines established on the basis of clinical trials. Those trials, generally employing sinusoidal waveforms, tested human responses to magnetic fields at frequencies between 0.5 and 10 kHz [W. Irnich and F. Schmitt, Magn. Reson. Med. 33, 619–623 (1995), T. F. Budinger et al., J. Comput. Assist. Tomogr. 15, 909–914 (1991), and D. J. Schaefer et al., J. Magn. Reson. Imaging12, 20–29 (2000)]. PNS thresholds for frequencies higher than 10 kHz had been extrapolated, using physiological models [J. P. Reilly et al., IEEE Trans. Biomed. Eng. BME-32(12), 1001–1011 (1985)]. The present study provides experimental data on human PNS thresholds to oscillating magnetic field stimulation from 2 to 183 kHz. Sinusoidal waveforms were employed for several reasons: (1) to facilitate comparison with earlier reports that used sine waves, (2) because prior designers of fast gradient hardware for generalized waveforms (e.g., including trapezoidal pulses) have employed quarter-sine-wave resonant circuits to reduce the rise- and fall-times of pulse waveforms, and (3) because sinusoids are often used in fast pulse sequences (e.g., spiral scans) [S. Nowak, U.S. patent 5,245,287 (14 September 1993) and K. F. King and D. J. Schaefer, J. Magn. Reson. Imaging12, 164–170 (2000)].

Methods:

An IRB-approved prospective clinical trial was performed, involving 26 adults, in which one wrist was exposed to decaying sinusoidal magnetic field pulses at frequencies from 2 to 183 kHz and amplitudes up to 0.4 T. Sham exposures (i.e., with no magnetic fields) were applied to all subjects.

Results:

For 0.4 T pulses at 2, 25, 59, 101, and 183 kHz, stimulation was reported by 22 (84.6%), 24 (92.3%), 15 (57.7%), 2 (7.7%), and 1 (3.8%) subjects, respectively.

Conclusions:

The probability of PNS due to brief biphasic time-varying sinusoidal magnetic fields with magnetic excursions up to 0.4 T is shown to decrease significantly at and above 101 kHz. This phenomenon may have particular uses in dynamic scenarios (e.g., cardiacimaging) and in studying processes with short decay times (e.g., electron paramagnetic resonance imaging, bone and solids imaging). The study suggests the possibility of new designs for human and preclinical MRI systems that may be useful in clinical practice and scientific research.

Loading

Full text loading...

/deliver/fulltext/aapm/journal/medphys/39/5/1.3702775.html;jsessionid=6pji68istk8a5.x-aip-live-06?itemId=/content/aapm/journal/medphys/39/5/10.1118/1.3702775&mimeType=html&fmt=ahah&containerItemId=content/aapm/journal/medphys

Most read this month

Article
content/aapm/journal/medphys
Journal
5
3
Loading

Most cited this month

true
true
This is a required field
Please enter a valid email address
This feature is disabled while Scitation upgrades its access control system.
This feature is disabled while Scitation upgrades its access control system.
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Increasing the oscillation frequency of strong magnetic fields above 101 kHz significantly raises peripheral nerve excitation thresholds
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/39/5/10.1118/1.3702775
10.1118/1.3702775
SEARCH_EXPAND_ITEM