1887
banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
oa
The effect of small field output factor measurements on IMRT dosimetry
Rent:
Rent this article for
Access full text Article
/content/aapm/journal/medphys/39/8/10.1118/1.4736527
1.
1. R. K. Rice, J. L. Hansen, G. K. Svensson, and R. L. Siddon, “Measurements of dose distributions in small beams of 6 MV x-rays,” Phys. Med. Biol. 32, 10871099 (1987).
http://dx.doi.org/10.1088/0031-9155/32/9/002
2.
2. L. B. Leybovich, A. Sethi, and N. Dogan, “Comparison of ionization chambers of various volumes for IMRT absolute dose verification,” Med. Phys. 30, 119123 (2003).
http://dx.doi.org/10.1118/1.1536161
3.
3. W. Laub and T. Wong, “The volume effect of detectors in the dosimetry of small fields used in IMRT,” Med. Phys. 30, 341347 (2003).
http://dx.doi.org/10.1118/1.1544678
4.
4. F. Haryanto, M. Fippel, W. Laub, O Dohm, and F. Nusslin, “Investigation of photon beam output factors for conformal radiation therapy-Monte Carlo simulations and measurements,” Phys. Med. Biol. 47, N133N143 (2002).
http://dx.doi.org/10.1088/0031-9155/47/11/401
5.
5. F. M. Khan, The Physics of Radiation Therapy, 4th ed. (LWW, Philadelphia, 2008).
6.
6. I. J. Das, G. X. Ding, and A. Ahnesjo, “Small fields: Nonequilibrium radiation dosimetry,” Med. Phys. 35, 206215 (2008).
http://dx.doi.org/10.1118/1.2815356
7.
7. T. C. Zhu et al., “Report of AAPM Therapy Physics Committee Task Group 74: In-air output ratio, Sc, for megavoltage photon beams,” Med. Phys. 36, 52615291 (2009).
http://dx.doi.org/10.1118/1.3227367
8.
8. T. C. Zhu and B. E. Bjarngard, “The head-scatter factor for small field sizes,” Med. Phys. 21, 6568 (1994).
http://dx.doi.org/10.1118/1.597256
9.
9. T. R. Mackie, J. W. Scrimger, and J. J. Battista, “A convolution method of calculating dose for 15 MV x rays,” Med. Phys. 12, 188196 (1985).
http://dx.doi.org/10.1118/1.595774
10.
10. A. Ahnesjo, “Analytic modeling of photon scatter from flattening filters in photon therapy beams,” Med. Phys. 21, 12271235 (1994).
http://dx.doi.org/10.1118/1.597205
11.
11. Pinnacle3 Physics Reference Guide, Philips Medical Systems (2006).
12.
12. S. Kim, T. C. Zhu, and J. R. Palta, “An equivalent square field formula for determining head scatter factors of rectangular fields,” Med. Phys. 24, 17701774 (1997).
http://dx.doi.org/10.1118/1.597963
13.
13. S. Kim, J. R. Palta, and T. C. Zhu, “A generalized solution for the calculation of in-air output factors in irregular fields,” Med. Phys. 25, 16921701 (1998).
http://dx.doi.org/10.1118/1.598350
14.
14. B. Hårdemark, A. Liander, H. Rehbinder, and J. Löf, “Direct Machine Parameter Optimization,” Pinnacle3 White Paper (2004).
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/39/8/10.1118/1.4736527
Loading
/content/aapm/journal/medphys/39/8/10.1118/1.4736527
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aapm/journal/medphys/39/8/10.1118/1.4736527
2012-07-18
2014-07-24

Abstract

Purpose:

To evaluate how changes in the measured small field output factors affect the doses in intensity-modulated treatment planning.

Methods:

IMRT plans were created using Philips Pinnacle treatment planning system. The plans were optimized to treat a cylindrical target 2 cm in diameter and 2 cm in length. Output factors for 2 × 2 and 3 × 3 cm2field sizes were changed by ±5%, ±10%, and ±20% increments from the baseline measurements and entered into the planning system. The treatment units were recommissioned in the treatment planning system after each modification of the output factors and treatment plans were reoptimized. All plans were delivered to a solid water phantom and dose measurements were made using an ionization chamber. The percentage differences between measured and computed doses were calculated. An Elekta Synergy and a Varian 2300CD linear accelerator were separately evaluated.

Results:

For the Elekta unit, decreasing the output factors resulted in higher measured than computed doses by 0.8% for −5%, 3.6% for −10%, and 8.7% for −20% steps. Increasing the output factors resulted in lower doses by 2.9% for +5%, 5.4% for +10%, and 8.3% for +20% steps. For the Varian unit no changes were observed for either increased or decreased output factors.

Conclusions:

The measurement accuracy of small field output factors are of importance especially when the treatment plan consists of small segments as in IMRT. The method proposed here could be used to verify the accuracy of the measured small field output factors for certain linear accelerators as well as to test the beam model. The Pinnacle treatment planning system model uses output factors as a function of jaw setting. Consequently, plans using the Elekta unit, which conforms the jaws to the segments, are sensitive to small field measurement accuracy. On the other hand, for the Varian unit, jaws are fixed and segments are modeled as blocked fields hence, the impact of small field output factors on IMRT monitor unit calculation is not evaluable by this method.

Loading

Full text loading...

/deliver/fulltext/aapm/journal/medphys/39/8/1.4736527.html;jsessionid=x199osiemcmp.x-aip-live-06?itemId=/content/aapm/journal/medphys/39/8/10.1118/1.4736527&mimeType=html&fmt=ahah&containerItemId=content/aapm/journal/medphys
true
true
This is a required field
Please enter a valid email address
This feature is disabled while Scitation upgrades its access control system.
This feature is disabled while Scitation upgrades its access control system.
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: The effect of small field output factor measurements on IMRT dosimetry
http://aip.metastore.ingenta.com/content/aapm/journal/medphys/39/8/10.1118/1.4736527
10.1118/1.4736527
SEARCH_EXPAND_ITEM