Skip to main content
banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
The full text of this article is not currently available.
1.R. R. Wilson, “Radiological use of fast protons,” Radiology 47, 487491 (1946).
2.Particle Therapy Co-Operative Group, cited May 30, 2015.
3.M. Urie, M. Goitein, W. R. Holley, and G. T. Chen, “Degradation of the Bragg peak due to inhomogeneities,” Phys. Med. Biol. 31(1), 115 (1986).
4.G. O. Sawakuchi, U. Titt, D. Mirkovic, and R. Mohan, “Density heterogeneities and the influence of multiple Coulomb and nuclear scatterings on the Bragg peak distal edge of proton therapy beams,” Phys. Med. Biol. 53(17), 46054619 (2008).
5.S. Espana and H. Paganetti, “Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapy,” Phys. Med. Biol. 56(13), 38433856 (2011).
6.L. S. Waters, J. Hendricks, and G. McKinney, mcnpx version 2.5.0., Los Alamos National Laboratory, Los Alamos, 2005.
7.ICRU, “Tissue substitutes in radiation dosimetry and measurement,” ICRU Report 44, International Commission on Radiation Units and Measurements, 1989.
8.S. E. Kuhn and G. E. Dodge, “A fast algorithm for Monte Carlo simulations of multiple Coulomb scattering,” Nucl. Instrum. Methods Phys. Res., Sect. A 322, 8892 (1992).
9.A. Stankowskiy, S. Kerhoas-Cavata, R. Ferrand, C. Nauraye, and L. Demarzi, “Monte Carlo modelling of the treatment line of the proton therapy center in Orsay,” Phys. Med. Biol. 54, 23772394 (2009).

Data & Media loading...


Article metrics loading...



The purpose of the work reported here was to investigate the influence of sub-millimeter size heterogeneities on the degradation of the distal edges of proton beams and to validate Monte Carlo (MC) methods’ ability to correctly predict such degradation.

A custom-designed high-resolution plastic phantom approximating highly heterogeneous, lung-like structures was employed in measurements and in Monte Carlo simulations to evaluate the degradation of proton Bragg curves penetrating heterogeneous media.

Significant differences in distal falloff widths and in peak dose values were observed in the measured and the Monte Carlo simulated curves compared to pristine proton Bragg curves. Furthermore, differences between simulations of beams penetrating CT images of the phantom did not agree well with the corresponding experimental differences. The distal falloff widths in CT image-based geometries were underestimated by up to 0.2 cm in water (corresponding to 0.8–1.4 cm in lung tissue), and the peak dose values of pristine proton beams were overestimated by as much as ˜35% compared to measured curves or depth-dose curves simulated on the basis of true geometry. The authors demonstrate that these discrepancies were caused by the limited spatial resolution of CT images that served as a basis for dose calculations and lead to underestimation of the impact of the fine structure of tissue heterogeneities. A convolution model was successfully applied to mitigate the underestimation.

The results of this study justify further development of models to better represent heterogeneity effects in soft-tissue geometries, such as lung, and to correct systematic underestimation of the degradation of the distal edge of proton doses.