Skip to main content

News about Scitation

In December 2016 Scitation will launch with a new design, enhanced navigation and a much improved user experience.

To ensure a smooth transition, from today, we are temporarily stopping new account registration and single article purchases. If you already have an account you can continue to use the site as normal.

For help or more information please visit our FAQs.

banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
The full text of this article is not currently available.
/content/aip/journal/adva/5/10/10.1063/1.4934720
1.
1.S. Yanabu, H. Murase, H. Aoyagi, H. Okubo, and Y. Kawaguchi, IEEE Trans. Power Del. 5(4), 18751882 (1990).
http://dx.doi.org/10.1109/61.103684
2.
2.A. Garzarella, S. B. Qadri, T. J. Wieting, and D. H. Wu, J. Appl. Phys. 98(4), 43113 (2005).
http://dx.doi.org/10.1063/1.2030414
3.
3.F. Cecelja and W. Balachandran, IEE Proc. Sci. Meas. Technol. 147(4), 165168 (2000).
http://dx.doi.org/10.1049/ip-smt:20000254
4.
4.S. A. Boggs and N. Fujimoto, IEEE Trans. Electr. Insul. 19(2), 8792 (1984).
http://dx.doi.org/10.1109/TEI.1984.298778
5.
5.W. Feser and W. Pfaff, IEEE Trans. Power App. Syst. PAS-103(10), 29042911 (1984).
http://dx.doi.org/10.1109/TPAS.1984.318292
6.
6.A. Garzarella, S. B. Qadri, D. H. Wu, and R. J. Hinton, Appl. Opt. 46(26), 66366640 (2007).
http://dx.doi.org/10.1364/AO.46.006636
7.
7.A. Kumada, M. Chiba, and K. Hidaka, J Appl Phys 84(6), 30593065 (1998).
http://dx.doi.org/10.1063/1.368460
8.
8.A. Kumada and K. Hidaka, IEEE Trans. Power Del. 28(3), 13061313 (2013).
http://dx.doi.org/10.1109/TPWRD.2013.2250315
9.
9.A. Garzarella, S. B. Qadri, T. J. Wieting, D. H. Wu, and R. J. Hinton, Opt. Lett. 32(8), 964966 (2007).
http://dx.doi.org/10.1364/OL.32.000964
10.
10.M. Zhu, X. Chen, Z. Du, and J. Ma, AIP Advances. 1, 42163 (2011).
http://dx.doi.org/10.1063/1.3668284
11.
11.A. Kumada, Y. Shimizu, M. Chiba, and K. Hidaka, J. Electrost. 58(1), 4558 (2003).
http://dx.doi.org/10.1016/S0304-3886(02)00189-4
12.
12.Y. Tian, P. L. Lewin, D. Pommerenke, S. Wilkinson, and S. J. Sutton, IEEE Trans. Dielectr. Electr. Insul. 11(5), 861869 (2004).
http://dx.doi.org/10.1109/TDEI.2004.1349792
13.
13.G. E. Jellison, S. Auluck, D. J. Singh, and L. A. Boatner, J Appl Phys. 107(1), 13514 (2010).
http://dx.doi.org/10.1063/1.3272909
14.
14.R. Zeng, B. Wang, Z. Yu, B. Niu, and Y. Hua, Opt. Eng. 50(11), 114404 (2011).
http://dx.doi.org/10.1117/1.3651809
15.
15.R. Zeng, C. Zhuang, Z. Yu, Z. Li, and Y. Geng, Appl. Phys. Lett. 99(22), 221503 (2011).
http://dx.doi.org/10.1063/1.3665633
16.
16.Y. Yue and J. He, Rev. Sci. Instrum. 84(8), 85107 (2013).
http://dx.doi.org/10.1063/1.4817208
17.
17.M. Schwerdt, J. Berger, B. Schuppert, and K. Petermann, IEEE Trans. Electromagn. Compat. 39(4), 386390 (1997).
http://dx.doi.org/10.1109/15.649844
18.
18.H. Yamashita, H. Amano, and T. Mori, J. Phys. D: Appl. Phys. 10, 1753 (1977).
http://dx.doi.org/10.1088/0022-3727/10/13/010
19.
19.B. Saleh, M. Teich, and R. Slusher, Fundamentals of Photonics (Wiley, New York, 2007), pp. 837840.
http://aip.metastore.ingenta.com/content/aip/journal/adva/5/10/10.1063/1.4934720
Loading
/content/aip/journal/adva/5/10/10.1063/1.4934720
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/adva/5/10/10.1063/1.4934720
2015-10-22
2016-12-05

Abstract

Intense transient electric field measurements are widely applied in various research areas. An optical intense E-field sensor for time-domain measurements, based on the electro-optic effect of lithium niobate, has been studied in detail. Principles and key issues in the design of the sensor are presented. The sensor is insulated, small in size (65 mm × 15 mm × 15 mm), and suitable for high-intensity (<801 kV/m) electric field measurements over a wide frequency band (10 Hz–10 MHz). The input/output characteristics of the sensor were obtained and the sensor calibrated. Finally, an application using this sensor in testing laboratory lightning impulses and in measuring transient electric fields during switch-on of a disconnector confirmed that the sensor is expected to find widespread use in transient intense electric field measurement applications.

Loading

Full text loading...

/deliver/fulltext/aip/journal/adva/5/10/1.4934720.html;jsessionid=zvL6FT9bfoL5A6ed6xApnCZA.x-aip-live-06?itemId=/content/aip/journal/adva/5/10/10.1063/1.4934720&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/adva
true
true

Access Key

  • FFree Content
  • OAOpen Access Content
  • SSubscribed Content
  • TFree Trial Content
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
/content/realmedia?fmt=ahah&adPositionList=
&advertTargetUrl=//oascentral.aip.org/RealMedia/ads/&sitePageValue=aipadvances.aip.org/5/10/10.1063/1.4934720&pageURL=http://scitation.aip.org/content/aip/journal/adva/5/10/10.1063/1.4934720'
Right1,Right2,Right3,