Skip to main content

News about Scitation

In December 2016 Scitation will launch with a new design, enhanced navigation and a much improved user experience.

To ensure a smooth transition, from today, we are temporarily stopping new account registration and single article purchases. If you already have an account you can continue to use the site as normal.

For help or more information please visit our FAQs.

banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
The full text of this article is not currently available.
/content/aip/journal/adva/6/3/10.1063/1.4942669
1.
1.Y. Z. Ider and S. Onart, Physiol. Meas. 25, 281 (2004).
http://dx.doi.org/10.1088/0967-3334/25/1/032
2.
2.M. J. Hamamura, L. T. Muftuler, O. Birgul, and O. Nalcioglu, Phys. Med. Biol. 51, 2753 (2006).
http://dx.doi.org/10.1088/0031-9155/51/11/005
3.
3.E. Degirmenci and M. Eyuboglu, IEEE Trans. Med. Imag. 601 (2013).
http://dx.doi.org/10.1109/TMI.2012.2231872
4.
4.O. I. kwon, W. C. Jeong, S. Z. K. Sajib, H. J. Kim, and E. J. Woo, Phys. Med. Biol. 59, 2955 (2014).
http://dx.doi.org/10.1088/0031-9155/59/12/2955
5.
5.M. Kranjc, B. Markelc, F. Bajd, M. Cemazar, I. Sersa, T. Blagus, and D. Miklavcic, Radiology 274, 115 (2015).
http://dx.doi.org/10.1148/radiol.14140311
6.
6.M. L. G. Joy, G. C. Scott, and R. M. Henkelman, Magn. Reson. Med. 7, 89 (1989).
7.
7.G. C. Scott, M. L. G. Joy, R. L. Armstrong, and R. M. Henkelman, IEEE Trans. Med. Imag. 10, 362 (1991).
http://dx.doi.org/10.1109/42.97586
8.
8.R. Sadleir, S. Grant, S. U. Zhang, B. I. Lee, H. C. Pyo, S. H. Oh, C. Park, E. J. Woo, S. Y. Lee, O. I. Kwon, and J. K. Seo, Physiol. Meas. 26, 875 (2005).
http://dx.doi.org/10.1088/0967-3334/26/5/023
9.
9.G. C. Scott, M. L. G. Joy, R. L. Armstrong, and R. M. Henkelman, J. of Magn. Reson. 97, 235 (1992).
10.
10.H. S. Nam and O. I. Kwon, Phys. Med. Biol. 55, 2743 (2010).
http://dx.doi.org/10.1088/0031-9155/55/9/021
11.
11.T. I. Oh, H. J. Kim, W. C. Jeong, H. Wi, O. I. Kwon, and E. J. Woo, BioMed. Eng. 13, 87 (2014).
http://aip.metastore.ingenta.com/content/aip/journal/adva/6/3/10.1063/1.4942669
Loading
/content/aip/journal/adva/6/3/10.1063/1.4942669
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/adva/6/3/10.1063/1.4942669
2016-03-21
2016-12-10

Abstract

Measuring the -component of magnetic flux density = (, , ) induced by transversally injected current,magnetic resonance electrical impedance tomography (MREIT) aims to visualize electrical property (current density and/or conductivity distribution) in a three-dimensional imaging object. For practical implementations of MREIT technique, it is critical to reduce injection of current pulse within safety requirements. With the goal of minimizing the noise level in measured data, we propose a new method to enhance the measure data using steady-state coherent gradient multi-echo (SSC-GME) MR pulse sequence combining with injection current nonlinear encoding (ICNE) method in MREIT, where the ICNE technique injects current during a readout gradient to maximize the signal intensity of phase signal including . The total phase offset in SSC-GME includes additional magnetic flux density due to the injected current, which is different from the phase signal for the conventional spoiled MR pulse sequence. We decompose the magnetization precession phase from the total phase offset including and optimize data using the steady-state equilibrium signal. Results from a real phantom experiment including different kinds of anomalies demonstrated that the proposed method enhanced comparing to a conventional spoiled pulse sequence.

Loading

Full text loading...

/deliver/fulltext/aip/journal/adva/6/3/1.4942669.html;jsessionid=ihFyIaVK5duGFMmlEYTHAFn1.x-aip-live-03?itemId=/content/aip/journal/adva/6/3/10.1063/1.4942669&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/adva
true
true

Access Key

  • FFree Content
  • OAOpen Access Content
  • SSubscribed Content
  • TFree Trial Content
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
/content/realmedia?fmt=ahah&adPositionList=
&advertTargetUrl=//oascentral.aip.org/RealMedia/ads/&sitePageValue=aipadvances.aip.org/6/3/10.1063/1.4942669&pageURL=http://scitation.aip.org/content/aip/journal/adva/6/3/10.1063/1.4942669'
Right1,Right2,Right3,