Skip to main content

News about Scitation

In December 2016 Scitation will launch with a new design, enhanced navigation and a much improved user experience.

To ensure a smooth transition, from today, we are temporarily stopping new account registration and single article purchases. If you already have an account you can continue to use the site as normal.

For help or more information please visit our FAQs.

banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
The full text of this article is not currently available.
/content/aip/journal/apl/107/6/10.1063/1.4926859
1.
1. F. W. Roemer and A. Guermazi, Osteoarthritis Cartilage 22(12), 2003 (2014).
http://dx.doi.org/10.1016/j.joca.2014.07.012
2.
2. F. W. Roemer, M. D. Crema, S. Trattnig, and A. Guermazi, Radiology 260(2), 332 (2011).
http://dx.doi.org/10.1148/radiol.11101359
3.
3. Z. Yuan, Q. Zhang, H. Jiang, E. Sobel, and H. Jiang, Biomed. Opt. Express 1(1), 74 (2010).
http://dx.doi.org/10.1364/BOE.1.000074
4.
4. A. H. Hielscher, A. D. Klose, A. K. Scheel, B. Moa-Anderson, M. Backhaus, U. Netz, and J. Beuthan, Phys. Med. Biol. 49(7), 1147 (2004).
http://dx.doi.org/10.1088/0031-9155/49/7/005
5.
5. L. V. Wang and S. Hu, Science 335(6075), 1458 (2012).
http://dx.doi.org/10.1126/science.1216210
6.
6. P. Beard, Interface Focus 1(4), 602 (2011).
http://dx.doi.org/10.1098/rsfs.2011.0028
7.
7. L. Xi, S. Grobmyer, L. Wu, R. Chen, G. Zhou, L. G. Gutwein, J. Sun, W. Liao, Q. Zhou, H. Xie, and H. Jiang, Opt. Express 20(8), 8726 (2012).
http://dx.doi.org/10.1364/OE.20.008726
8.
8. L. Xiang, B. Wang, L. Ji, and H. Jiang, Sci. Rep. 3, 1113 (2013).
http://dx.doi.org/10.1038/srep01113
9.
9. S. Yang, D. Xing, Q. Zhou, L. Xiang, and Y. Lao, Med. Phys. 34(8), 3294 (2007).
http://dx.doi.org/10.1118/1.2757088
10.
10. X. Wang, D. L. Chamberland, and D. A. Jamadar, Opt. Lett. 32(20), 3002 (2007).
http://dx.doi.org/10.1364/OL.32.003002
11.
11. Y. Sun, E. Sobel, and H. Jiang, J. Biomed. Opt. 14(6), 064002 (2009).
http://dx.doi.org/10.1117/1.3257246
12.
12. P. van Es, S. K. Biswas, H. J. Bernelot Moens, W. Steenbergen, and S. Manohar, J. Biomed. Opt. 19(6), 060501 (2014).
http://dx.doi.org/10.1117/1.JBO.19.6.060501
13.
13. C. Lutzweiler, R. Meier, E. Rummeny, V. Ntziachristos, and D. Razansky, Opt. Lett. 39(14), 4061 (2014).
http://dx.doi.org/10.1364/OL.39.004061
14.
14. G. Xu, J. R. Rajian, G. Girish, M. J. Kaplan, J. B. Fowlkes, P. L. Carson, and X. Wang, J. Biomed. Opt. 18(1), 010502 (2013).
http://dx.doi.org/10.1117/1.JBO.18.1.010502
15.
15. L. Nie, Z. Guo, and L. V. Wang, J. Biomed. Opt. 16(7), 076005 (2011).
http://dx.doi.org/10.1117/1.3595842
16.
16. C. Li and L. V. Wang, J. Biomed. Opt. 14(2), 024047 (2009).
http://dx.doi.org/10.1117/1.3122365
17.
17. J. Xiao, L. Yao, Y. Sun, E. Sobel, J. He, and H. Jiang, Opt. Express 18(14), 1435914365 (2010).
http://dx.doi.org/10.1364/OE.18.014359
18.
18. H. Ammari, E. Bossy, V. Jugnon, and H. Kang, SIAM Rev. 52(4), 677695 (2010).
http://dx.doi.org/10.1137/090748494
19.
19. C. Song, L. Xi, and H. Jiang, J. Appl. Phys. 114(19), 194703 (2013).
http://dx.doi.org/10.1063/1.4832757
20.
20. C. Song, L. Xi, and H. Jiang, Opt. Lett. 38(15), 2930 (2013).
http://dx.doi.org/10.1364/OL.38.002930
21.
21. Z. Yuan, Q. Wang, and H. Jiang, Opt. Express 15(26), 1807618081 (2007).
http://dx.doi.org/10.1364/OE.15.018076
http://aip.metastore.ingenta.com/content/aip/journal/apl/107/6/10.1063/1.4926859
Loading
/content/aip/journal/apl/107/6/10.1063/1.4926859
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/apl/107/6/10.1063/1.4926859
2015-08-11
2016-12-03

Abstract

We present a method for noninvasively imaging the hand joints using a three-dimensional (3D) photoacoustic imaging (PAI) system. This 3D PAI system utilizes cylindrical scanning in data collection and virtual-detector concept in image reconstruction. The maximum lateral and axial resolutions of the PAI system are 70 m and 240 m. The cross-sectional photoacoustic images of a healthy joint clearly exhibited major internal structures including phalanx and tendons, which are not available from the current photoacoustic imaging methods. The PAI results obtained are comparable with the corresponding 3.0 T MRI images of the finger joint. This study suggests that the proposed method has the potential to be used in early detection of joint diseases such as osteoarthritis.

Loading

Full text loading...

/deliver/fulltext/aip/journal/apl/107/6/1.4926859.html;jsessionid=dVVdDGoo44eBED6xQkOtS8Aa.x-aip-live-06?itemId=/content/aip/journal/apl/107/6/10.1063/1.4926859&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/apl
true
true

Access Key

  • FFree Content
  • OAOpen Access Content
  • SSubscribed Content
  • TFree Trial Content
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
/content/realmedia?fmt=ahah&adPositionList=
&advertTargetUrl=//oascentral.aip.org/RealMedia/ads/&sitePageValue=apl.aip.org/107/6/10.1063/1.4926859&pageURL=http://scitation.aip.org/content/aip/journal/apl/107/6/10.1063/1.4926859'
x100,x101,x102,x103,
Position1,Position2,Position3,
Right1,Right2,Right3,