Controlling the alignment of neutral iodine molecules in the elliptical channels of crystals
Rent:
Rent this article for
USD
10.1063/1.2839374
/content/aip/journal/apl/92/4/10.1063/1.2839374
http://aip.metastore.ingenta.com/content/aip/journal/apl/92/4/10.1063/1.2839374
View: Figures

Figures

Image of FIG. 1.
FIG. 1.

(a) Scanning electron microscopy images of pristine AEL single crystals. (b) Model of the AEL crystal viewed along the (001) direction. (c) Schematic presentation of alignment of iodine molecules in the channels of AEL crystal.

Image of FIG. 2.
FIG. 2.

(a) Sketch show of the Raman scattering configuration. The incident excitation laser is polarized along the axis and propagates along the axis. The backscattered signals are along the axis. represents channels axis and is the polarization angle from the axis to the channel axis. (b) Raman spectra measured under the VV and VH configurations. The measurement method has been described in (a).

Image of FIG. 3.
FIG. 3.

(a) Sketch show of the Raman scattering configuration. The incident excitation laser is polarized along the axis and propagates along the axis. The backscattered signals are along the axis. represents channels axis and is the polarization angle from the axis to the channel axis. (b) Raman spectra measured under the VV and VH configurations. The measurement method has been described in (a).

Image of FIG. 4.
FIG. 4.

(a) Sketch show of the Raman scattering configuration. The incident excitation laser is polarized along the axis and propagates along the axis. The backscattered signals are along the axis. represents major axis of elliptical channel and is the polarization angle from the axis to the major axis of elliptical channel. (b) Raman spectra measured under the VV and VH configurations. The measurement method has been described in (a).

Loading

Article metrics loading...

/content/aip/journal/apl/92/4/10.1063/1.2839374
2008-01-30
2014-04-19
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Controlling the alignment of neutral iodine molecules in the elliptical channels of AlPO4-11 crystals
http://aip.metastore.ingenta.com/content/aip/journal/apl/92/4/10.1063/1.2839374
10.1063/1.2839374
SEARCH_EXPAND_ITEM