1887
banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
oa
Direct measurements of the frequency-dependent dielectrophoresis force
Rent:
Rent this article for
Access full text Article
/content/aip/journal/bmf/3/1/10.1063/1.3058569
1.
1.H. A. Pohl, J. Appl. Phys. 22, 869 (1951).
http://dx.doi.org/10.1063/1.1700065
2.
2.H. A. Pohl, J. Appl. Phys. 29, 1182 (1958).
http://dx.doi.org/10.1063/1.1723398
3.
3.P. R. C. Gascoyne and J. Vykoukal, Electrophoresis 23, 1973 (2002).
http://dx.doi.org/10.1002/1522-2683(200207)23:13<1973::AID-ELPS1973>3.0.CO;2-1
4.
4.H. D. Ou-Yang, in Polymer-Colloid Interactions: From Fundamentals To Practice, edited by P. Dubin and R. Farinato (Wiley, New York, 1999) Chap. 15, pp. 385405.
5.
5.L. A. Hough and H. D. Ou-Yang, Phys. Rev. E 65, 021906 (2002).
http://dx.doi.org/10.1103/PhysRevE.65.021906
6.
6.L. A. Hough and H. D. Ou-Yang, Phys. Rev. E 73, 031802 (2006).
http://dx.doi.org/10.1103/PhysRevE.73.031802
7.
7.M. T. Wei, A. Zaorski, H. C. Yalcin, J. Wang, M. Hallow, S. N. Ghadiali, A. Chiou, and H. D. Ou-Yang, Opt. Express 16, 8594 (2008).
http://dx.doi.org/10.1364/OE.16.008594
8.
8.N. G. Green and H. Morgan, J. Phys. Chem. B 103, 41 (1999).
http://dx.doi.org/10.1021/jp9829849
9.
9.A. R. Minerick and R. Pethig, American Electrophoresis Society Newsletter 10, 2 (2005).
10.
10.I. F. Cheng, H. C. Chang, D. Hou, and H.-C. Chang, Biomicrofluidics 1, 021503 (2007).
http://dx.doi.org/10.1063/1.2723669
11.
11.P. D. Hoffman, P. S. Sarangpapani, and Y. Zhu, Langmuir 24, 12164 (2008).
http://dx.doi.org/10.1021/la8013392
12.
12.P. D. Hoffman and Y. Zhu, Appl. Phys. Lett. 92, 224103 (2008).
http://dx.doi.org/10.1063/1.2938110
13.
13.J. E. Gordon, Z. Gagnon, and H. C. Chang, Biomicrofluidics 1, 044102 (2007).
http://dx.doi.org/10.1063/1.2818767
14.
14.F. F. Becker, X. -B. Wang, Y. Huang, R. Pethig, J. Vykoukal, and P. R. C. Gascoyne, Proc. Natl. Acad. Sci. U.S.A. 92, 860 (1995).
http://dx.doi.org/10.1073/pnas.92.3.860
15.
15.Z. Gagnon and H. C. Chang, Electrophoresis 26, 3725 (2005).
http://dx.doi.org/10.1002/elps.200500129
16.
16.M. P. Hughes and H. Morgan, J. Phys. D: Appl. Phys.31, 2205 (1998).
http://dx.doi.org/10.1088/0022-3727/31/17/020
17.
17.H. Morgan, M. P. Hughes, and N. G. Green, Biophys. J. 77, 516 (1999).
18.
18.M. Washizu, S. Suzuki, O. Kurosawa, T. Nishizaka, and T. Shinohara, IEEE Trans. Ind. Appl. 30, 835 (1994).
http://dx.doi.org/10.1109/28.297897
http://aip.metastore.ingenta.com/content/aip/journal/bmf/3/1/10.1063/1.3058569
Loading
/content/aip/journal/bmf/3/1/10.1063/1.3058569
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/bmf/3/1/10.1063/1.3058569
2009-01-02
2014-07-28

Abstract

Dielectrophoresis(DEP), the phenomenon of directed motion of electrically polarizable particles in a nonuniform electric field, is promising for applications in biochemical separation and filtration. For colloidal particles in suspension, the relaxation of the ionic species in the shear layer gives rise to a frequency-dependent, bidirectional DEP force in the radio frequency range. However, quantification methods of the DEP force on individual particles with the pico-Newton resolution required for the development of theories and design of device applications are lacking. We report the use of optical tweezers as a force sensor and a lock-in phase-sensitive technique for analysis of the particle motion in an amplitude modulated DEP force. The coherent detection and sensing scheme yielded not only unprecedented sensitivity for DEP force measurements, but also provided a selectivity that clearly distinguishes the pure DEP force from all the other forces in the system, including electrophoresis, electro-osmosis, heat-induced convection, and Brownian forces, all of which can hamper accurate measurements through other existing methods. Using optical tweezers-based force transducers already developed in our laboratory, we have results that quantify the frequency-dependent DEP force and the crossover frequency of individual particles with this new experimental method.

Loading

Full text loading...

/deliver/fulltext/aip/journal/bmf/3/1/1.3058569.html;jsessionid=15rci9ti9w8p.x-aip-live-03?itemId=/content/aip/journal/bmf/3/1/10.1063/1.3058569&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/bmf
true
true
This is a required field
Please enter a valid email address
This feature is disabled while Scitation upgrades its access control system.
This feature is disabled while Scitation upgrades its access control system.
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Direct measurements of the frequency-dependent dielectrophoresis force
http://aip.metastore.ingenta.com/content/aip/journal/bmf/3/1/10.1063/1.3058569
10.1063/1.3058569
SEARCH_EXPAND_ITEM