Human hand imaging using a 20 cm high-temperature superconducting coil in a 3T magnetic resonance imaging system
Rent:
Rent this article for
USD
10.1063/1.3431538
/content/aip/journal/jap/107/12/10.1063/1.3431538
http://aip.metastore.ingenta.com/content/aip/journal/jap/107/12/10.1063/1.3431538

Figures

Image of FIG. 1.
FIG. 1.

Matching and signal pick-up coils with variable tuning trimmer capacitor C1. Adjusting the capacitor C1, the imaginary part in Zin will be cancelled out of the resonant frequency.

Image of FIG. 2.
FIG. 2.

The 3T system setup of the phantom experiment, where the matching and signal pick-up coil with a tuning variable capacitance was put in the middle of the HTS tape coil and the phantom.

Image of FIG. 3.
FIG. 3.

Experiment setup to measure the QF.

Image of FIG. 4.
FIG. 4.

Coronal phantom images and mesh images comparison by Bruker fast spin echo sequence. The background noise of mesh image acquired from the HTS coil is significantly lower than that of the home-made copper coil. (a) Phantom image acquired from the home-made copper coil with . (b) Phantom image acquired from the HTS coil with . (c) Photograph of a 10 cm diameter spherical phantom filled with 10 mM . (d) Mesh image acquired from home-made copper coil. (e) Mesh image acquired from HTS coil.

Image of FIG. 5.
FIG. 5.

Plots of intensities along the horizontal axis extracted from phantom images, in which the dash, solid curves denote the HTS in 77 K and home-made copper coil at room temperature, respectively.

Image of FIG. 6.
FIG. 6.

Images of a human wrist by Bruker fast spin echo sequence with (a) the HTS coil at 77 K with the SNR of 195, (b) focal magnification of (a) which the interosseous muscle is visible, (c) the home-made copper coil at 300 K with SNR of 100, (d) focal magnification of (c) which the interosseeous muscle is not visible, and (e) the anatomy illustrations of (a).

Tables

Generic image for table
Table I.

General specification of Bi-2223 tapes.

Generic image for table
Table II.

QFs for HTS at 77 K and home-made copper coil at room temperature (Cu), : unloaded and : loaded (outside magnet).

Loading

Article metrics loading...

/content/aip/journal/jap/107/12/10.1063/1.3431538
2010-06-18
2014-04-18
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Human hand imaging using a 20 cm high-temperature superconducting coil in a 3T magnetic resonance imaging system
http://aip.metastore.ingenta.com/content/aip/journal/jap/107/12/10.1063/1.3431538
10.1063/1.3431538
SEARCH_EXPAND_ITEM