Wavelength dependence on the space charge collection in CdZnTe detectors
Rent:
Rent this article for
USD
10.1063/1.4725493
/content/aip/journal/jap/111/11/10.1063/1.4725493
http://aip.metastore.ingenta.com/content/aip/journal/jap/111/11/10.1063/1.4725493
View: Figures

Figures

Image of FIG. 1.
FIG. 1.

A schematic illustrating the illumination setup showing the position of the LED, bandpass filter, collimator, and CZT crystal. This setup can be used in either the (a) negative where the anode is located at the top and the cathode is at the bottom or (b) positive where the cathode is located at the top and the anode is at the bottom.

Image of FIG. 2.
FIG. 2.

An electric field distribution plot taken at room temperature is shown with multiple wavelengths of illumination including blue (blue circle), red (red triangle), and IR (purple diamond). A plot without LED illumination is also shown (black squares). A bias of −600 V (133 V mm−1) was maintained throughout the measurement.

Image of FIG. 3.
FIG. 3.

Electric field distribution plots are shown for multiple wavelengths of illumination including (a) IR (950 nm), (b) red (633 nm), and (c) blue (470 nm). A plot without LED illumination is also shown (d). Each wavelength figure is shown at both −600 V (133 V mm−1) with red triangles and −350 V (78 V mm−1) with black squares.

Image of FIG. 4.
FIG. 4.

An electric field distribution plot taken at room temperature is shown with multiple wavelengths of illumination including blue (blue circle), red (red triangle), and IR (purple diamond). A plot without LED illumination is also shown (black squares). A bias of +600 V (133 V mm−1) was maintained throughout the measurement.

Image of FIG. 5.
FIG. 5.

Electric field distribution plots are shown for multiple wavelengths of illumination including (a) IR (950 nm), (b) red (633 nm), and (c) blue (470 nm). A plot without LED illumination is also shown (d). Each wavelength Figure is shown at both +600 V (133 V mm−1) with red triangles and +350 V (78 V mm−1) with black squares.

Loading

Article metrics loading...

/content/aip/journal/jap/111/11/10.1063/1.4725493
2012-06-12
2014-04-23
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Wavelength dependence on the space charge collection in CdZnTe detectors
http://aip.metastore.ingenta.com/content/aip/journal/jap/111/11/10.1063/1.4725493
10.1063/1.4725493
SEARCH_EXPAND_ITEM