Target diagnostics for commissioning the AWE HELEN Laser Facility chirped pulse amplification beam
Rent:
Rent this article for
USD
10.1063/1.2236280
/content/aip/journal/rsi/77/10/10.1063/1.2236280
http://aip.metastore.ingenta.com/content/aip/journal/rsi/77/10/10.1063/1.2236280
View: Figures

Figures

Image of FIG. 1.
FIG. 1.

HELEN Laser target interaction chamber showing the beam path of the short-pulse (CPA) beam and the beam cones for the long pulse beams.

Image of FIG. 2.
FIG. 2.

(a) Predicted focal spot intensity distribution calculated from aberration corrected beam wave front data, (b) line profile through calculated focal spot diameter showing diameter of the first dark ring of the Airy-disk like intensity distribution.

Image of FIG. 3.
FIG. 3.

X-ray pinhole image of laser heat spot of CPA beam at best focus on an aluminium target foil. Pinhole diameter is filtered by a thick aluminium foil.

Image of FIG. 4.
FIG. 4.

Horizontal diameter line profile through x-ray pinhole image of laser heated spot. Raw data—gray and fit to data—solid.

Image of FIG. 5.
FIG. 5.

Maximum proton energy from time of flight measurements as a function of . HELEN CPA beam data in blocked in diamonds.

Image of FIG. 6.
FIG. 6.

(Color online) Scanned images of radiochromic film (upper) and CR39 (lower) stack for a focused intensity of on thick aluminium foil showing signal principally due to energetic protons. Stack sequence from front to back: Al/RCF(a)/CR39(a)/⋯/RCF(f)/CR39(f).

Image of FIG. 7.
FIG. 7.

Proton energy spectrum from calibrated radiochromic film/CR39 stack for a focused intensity of on thick aluminium foil target.

Image of FIG. 8.
FIG. 8.

Layout of TLD tungsten collimator array relative to the short-pulse laser axis. Each collimator contains five filtered capsules containing TLD powder.

Image of FIG. 9.
FIG. 9.

Relative spectral response of TLD detectors used in collimated array.

Image of FIG. 10.
FIG. 10.

Angular absorbed dose in filtered TLD array for at best focus incident of thick tantalum foil (HELEN—solid line) and thick tantalum (Vulcan laser—broken line).

Loading

Article metrics loading...

/content/aip/journal/rsi/77/10/10.1063/1.2236280
2006-10-09
2014-04-17
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Target diagnostics for commissioning the AWE HELEN Laser Facility 100TW chirped pulse amplification beam
http://aip.metastore.ingenta.com/content/aip/journal/rsi/77/10/10.1063/1.2236280
10.1063/1.2236280
SEARCH_EXPAND_ITEM