Image of FIG. 1.
FIG. 1.

Schematic view of the vacuum chamber for measurement of Seebeck coefficient and electrical resistivity.

Image of FIG. 2.
FIG. 2.

Top view (a) and side view (b) of the sample holder. The current leads in (a) are used to pass current in electrical resistance measurements.

Image of FIG. 3.
FIG. 3.

Circuit diagram of measuring Seebeck coefficient. The voltage signals sensed by TC1 and TC2 are recorded by multimeters V1 and V2, respectively, while the multimeter Vs is used to measure ΔU.

Image of FIG. 4.
FIG. 4.

Temperature variations on both sides of the sample (a), temperature difference ΔT (b), and thermoelectric voltage ΔU (c) across the sample as a function of time in a typical measurement cycle.

Image of FIG. 5.
FIG. 5.

The plot of ΔU vs. ΔT for the heating-up run (a) and cooling-down run (b) in the measurement cycle shown in Fig. 4 . Both cases demonstrate a clear linear relationship.

Image of FIG. 6.
FIG. 6.

Measurement of Seebeck coefficient of constantan as a function of temperature. The measured data are derived from both heating-up and cooling-down runs.

Image of FIG. 7.
FIG. 7.

The temperature dependent Seebeck coefficient of platinum. The measured results which are obtained from both heating-up and cooling-down runs match reasonably well with the literatures.

Image of FIG. 8.
FIG. 8.

The measured resistivity of platinum in comparison with the literature data. An exciting current of 100 mA was used in the test.

Loading

Article metrics loading...

/content/aip/journal/rsi/84/4/10.1063/1.4798647
2013-04-04
2014-04-16
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: An experimental apparatus for simultaneously measuring Seebeck coefficient and electrical resistivity from 100 K to 600 K
http://aip.metastore.ingenta.com/content/aip/journal/rsi/84/4/10.1063/1.4798647
10.1063/1.4798647
SEARCH_EXPAND_ITEM