oa
Note: Magnetic noise from the inner wall of a magnetically shielded room
Rent:
Rent this article for
Access full text Article
/content/aip/journal/rsi/84/5/10.1063/1.4802845
1.
1. D. Cohen, Science 175, 664 (1972).
http://dx.doi.org/10.1126/science.175.4022.664
2.
2. R. Salmelin and S. Baillet, Hum. Brain Mapp 30, 1753 (2009).
http://dx.doi.org/10.1002/hbm.20795
3.
3. D. Cohen, U. Schlapfer, S. Ahlfors, M. Hamalainen, and E. Halgren, in Biomag 96: Proceedings of the 13th International Conference on Biomagnetism, edited by H. Nowak, J. Haueisen, F. Giessler, and R. Huonker (VDE, Berlin, 1997), p. 399.
4.
4. J. A. Sidles, J. L. Garbini, W. M. Dougherty, and Shih-hui Chao, Proc. IEEE 91(5), 799 (2003).
http://dx.doi.org/10.1109/JPROC.2003.811796
5.
5. J. Nenonen and T. Katila, in: Biomag 87: Proceedings of the 6th International Conference on Biomagnetism, edited by K. Atsumi, M. Kotani, S. Ueno, T. Katila, and S. J. Williamson (Denki University Press, Tokyo, 1988), p. 426.
6.
6. J. Nenonen, J. Montonen, and T. Katila, Rev. Sci. Instrum. 67, 2397 (1996).
http://dx.doi.org/10.1063/1.1147514
7.
7. T. W. Kornack, S. J. Smullin, S-K. Lee, and M. V. Romalis, Appl. Phys. Lett. 90, 223501 (2007).
http://dx.doi.org/10.1063/1.2737357
8.
8. S. K. Lee and M. V. Romalis, J. Appl. Phys. 103, 084904 (2008).
http://dx.doi.org/10.1063/1.2885711
9.
9. F. Tadel, S. Baillet, J. C. Mosher, D. Pantazis, and R. M. Leahy, Comput. Intell. Neurosci. 2011, 879716 (2011).
http://dx.doi.org/10.1155/2011/879716
10.
10. M. Hamalainen, R. Hari, R. J. Ilmoniemi, J. Knuutila, and O. V. Lounasmaa, Rev. Mod. Phys. 65, 413 (1993).
http://dx.doi.org/10.1103/RevModPhys.65.413
http://aip.metastore.ingenta.com/content/aip/journal/rsi/84/5/10.1063/1.4802845
Loading
/content/aip/journal/rsi/84/5/10.1063/1.4802845
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/rsi/84/5/10.1063/1.4802845
2013-05-01
2014-09-21

Abstract

We measured the thermal magnetic noise generated by the inner high-permeability wall of a magnetically shielded room. This room houses a magnetoencephalogram (MEG), which contains 102 “small” identical magnetometers. For the measurement, we created two large magnetometers by summing the outputs of 46 magnetometers equally on the helmet's left and right side, to look at the summed noise of the right and left vertical walls. From these summed outputs, we calculated the rms noise amplitude due to all six walls at the MEG location to be ∼0.5 f T/ at 100 Hz, only slowly rising with lower frequency. This is well below the system noise of each small MEG magnetometer, hence is negligible for the MEG.

Loading

Full text loading...

/deliver/fulltext/aip/journal/rsi/84/5/1.4802845.html;jsessionid=wsoghg2ll9j2.x-aip-live-06?itemId=/content/aip/journal/rsi/84/5/10.1063/1.4802845&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/rsi
true
true
This is a required field
Please enter a valid email address
This feature is disabled while Scitation upgrades its access control system.
This feature is disabled while Scitation upgrades its access control system.