Application of dynamic displacement current for diagnostics of subnanosecond breakdowns in an inhomogeneous electric field
Rent:
Rent this article for
USD
10.1063/1.4807154
/content/aip/journal/rsi/84/5/10.1063/1.4807154
http://aip.metastore.ingenta.com/content/aip/journal/rsi/84/5/10.1063/1.4807154
View: Figures

Figures

Image of FIG. 1.
FIG. 1.

Design of the SLEP-150 generator with a gas diode and a collector (a), and output part of the generator with an additional transmission line, a gas diode and a shunt (b): (1) generator housing, (2) primary winding of the pulse transformer, (3) secondary winding of the pulse transformer, (4) insulator, (5) ferrite rings, (6) dielectric spacer, (7) brass ring, (8) peaking spark gap, (9) capacitive divider U, (10) high-voltage coaxial line of wave impedance 30 Ω, (11) short transmission line, (12,19) capacitive divider U, (13) discharge gap, (14) connector of the collector, (15) collector receiving part of diameter 20 mm, (16) foil with a diaphragm or a grid, (17) disk cathode with wires, (18, 25) inductance for charging the high-voltage coaxial line on the insulator, (20) additional transmission line, (21) capacitive divider U, (22) tubular cathode, (23) shunt, (24) insulator.

Image of FIG. 2.
FIG. 2.

Waveforms (the SLEP-150 generator with the additional transmission line) of the (a) incident voltage wave (1), superimposed incident and reflected voltage waves (2), (b) reflected voltage wave, (c) reconstructed voltage pulse across the gap (3), voltage pulse (4) from the capacitive divider (12) in Fig. 1(a) with tubular cathode and pulse of SAEB (5) from the second collector. Tubular cathode I, = 8 mm.

Image of FIG. 3.
FIG. 3.

Waveforms of the voltage from the capacitive divider , current from the shunt (a), current from the collector with the grid anode (b), and SAEB current downstream of the Al foil and diaphragm with a 18-mm hole diameter (c). Disk cathode, = 6 mm.

Image of FIG. 4.
FIG. 4.

Waveforms of the voltage from the capacitive divider , current from the shunt (a), current from the collector with the grid anode (b), and SAEB current downstream of the Al foil and diaphragm with a 2-mm hole diameter (c). Tubular cathode, = 12 mm.

Image of FIG. 5.
FIG. 5.

Waveforms of the voltage (a), current from the shunt (b), and conduction current (c).

Loading

Article metrics loading...

/content/aip/journal/rsi/84/5/10.1063/1.4807154
2013-05-22
2014-04-21
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Application of dynamic displacement current for diagnostics of subnanosecond breakdowns in an inhomogeneous electric field
http://aip.metastore.ingenta.com/content/aip/journal/rsi/84/5/10.1063/1.4807154
10.1063/1.4807154
SEARCH_EXPAND_ITEM