Design and calibration of high-frequency magnetic probes for the SUNIST spherical tokamaka)
a)Contributed paper, published as part of the Proceedings of the 20th Topical Conference on High-Temperature Plasma Diagnostics, Atlanta, Georgia, USA, June 2014.
Rent:
Rent this article for
Access full text Article
/content/aip/journal/rsi/85/11/10.1063/1.4886423
1.
1. P. V. Savrukhin and E. A. Shestakov, Rev. Sci. Instrum. 83, 013505 (2012).
http://dx.doi.org/10.1063/1.3675577
2.
2. M. J. Hole, L. C. Appel, and R. Martin, Rev. Sci. Instrum. 80, 123507 (2009).
http://dx.doi.org/10.1063/1.3272713
3.
3. C. A. Romero-Talamas, P. M. Bellan, and S. C. Hsu, Rev. Sci. Instrum. 75, 2664 (2004).
http://dx.doi.org/10.1063/1.1771483
4.
4. Y. Jeong-hun, K.-J. Chung, Y. An, B. K. Jung, J. G. Jo, and Y. S. Hwang, Rev. Sci. Instrum. 83, 10D721 (2012).
http://dx.doi.org/10.1063/1.4739224
5.
5. M. C. Thompson, J. D. Douglass, P. Feng, K. Knapp, Y. Luo, R. Mendoza, V. Patel, M. Tuszewski, and A. D. Van Drie, Rev. Sci. Instrum. 83, 10D709 (2012).
http://dx.doi.org/10.1063/1.4731760
6.
6. Y. X. He, Plasma Sci. Technol. 4, 1355 (2002).
http://dx.doi.org/10.1088/1009-0630/4/4/003
7.
7. R. F. Heeter, A. F. Fasoli, S. Ali-Arshad, and J. M. Moret, Rev. Sci. Instrum. 71, 4092 (2000).
http://dx.doi.org/10.1063/1.1313797
8.
8. F. D. Witherspoon, S. C. Prager, and J. C. Sprott, Phys. Rev. Lett. 53, 1559 (1984).
http://dx.doi.org/10.1103/PhysRevLett.53.1559
http://aip.metastore.ingenta.com/content/aip/journal/rsi/85/11/10.1063/1.4886423
Loading
/content/aip/journal/rsi/85/11/10.1063/1.4886423
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/rsi/85/11/10.1063/1.4886423
2014-07-10
2014-07-25

Abstract

A new high-frequency magnetic diagnostic system is designed, installed, and calibrated in the Sino-United Spherical Tokamak (SUNIST) to investigate Alfvén waves (AWs). The system consists of a fixed toroidal array and a movable radial array of high-frequency magnetic probes (HFMPs) with 21 and 60 probes, respectively. Based on the method of vacuum enameled wire wound on ceramic bobbins, the fixed toroidal array is located as near as possible to the plasma and carefully shielded to reduce the attenuation of high-frequency magnetic field. Meanwhile, by using the technology of commercial chip inductors mounted on printed circuit boards, the movable radial array is inserted into a thin quartz tube that allows positioning along radial direction. A Helmholtz coil is utilized to calibrate the effective areas as well as the frequency response of each HFMP. The calibration results are consistent with the calculated results of an equivalent probe-and-cable circuit model. High-frequency magnetic signals related to AW are detected with these HFMPs. These HFMPs are expected to play a key role in analyzing Alfvén eigenmodes excited by AW antenna in the SUNIST.

Loading

Full text loading...

/deliver/fulltext/aip/journal/rsi/85/11/1.4886423.html;jsessionid=2bs7fnmxxfjg8.x-aip-live-03?itemId=/content/aip/journal/rsi/85/11/10.1063/1.4886423&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/rsi
true
true
This is a required field
Please enter a valid email address
This feature is disabled while Scitation upgrades its access control system.
This feature is disabled while Scitation upgrades its access control system.
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Design and calibration of high-frequency magnetic probes for the SUNIST spherical tokamaka)
http://aip.metastore.ingenta.com/content/aip/journal/rsi/85/11/10.1063/1.4886423
10.1063/1.4886423
SEARCH_EXPAND_ITEM