Design of vibration compensation interferometer for Experimental Advanced Superconducting Tokamaka)
a)Contributed paper, published as part of the Proceedings of the 20th Topical Conference on High-Temperature Plasma Diagnostics, Atlanta, Georgia, USA, June 2014.
Rent:
Rent this article for
Access full text Article
/content/aip/journal/rsi/85/11/10.1063/1.4886455
1.
1. H. Q. Liu et al., JINST 8, C11002 (2013).
http://dx.doi.org/10.1088/1748-0221/8/11/C11002
2.
2. G. Braithwaite et al., Rev. Sci. Instrum. 60, 2825 (1989).
http://dx.doi.org/10.1063/1.1140666
3.
3. T. Akiyama et al., Rev. Sci. Instrum. 74, 1638 (2003).
http://dx.doi.org/10.1063/1.1532759
4.
4. K. Tanaka et al., Rev. Sci. Instrum. 75, 3429 (2004).
http://dx.doi.org/10.1063/1.1786643
5.
5. T. N. Carlstrom et al., Rev. Sci. Instrum. 59, 1063 (1988).
http://dx.doi.org/10.1063/1.1139726
6.
6. M. A. Van Zeeland et al., Rev. Sci. Instrum. 77, 10F325 (2006).
http://dx.doi.org/10.1063/1.2336437
http://aip.metastore.ingenta.com/content/aip/journal/rsi/85/11/10.1063/1.4886455
Loading
/content/aip/journal/rsi/85/11/10.1063/1.4886455
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/rsi/85/11/10.1063/1.4886455
2014-07-11
2014-08-02

Abstract

A vibration compensation interferometer (wavelength at 0.532 m) has been designed and tested for Experimental Advanced Superconducting Tokamak (EAST). It is designed as a sub-system for EAST far-infrared (wavelength at 432.5 m) poloarimeter/interferometer system. Two Acoustic Optical Modulators have been applied to produce the 1 MHz intermediate frequency. The path length drift of the system is lower than 2 wavelengths within 10 min test, showing the system stability. The system sensitivity has been tested by applying a periodic vibration source on one mirror in the system. The vibration is measured and the result matches the source period. The system is expected to be installed on EAST by the end of 2014.

Loading

Full text loading...

/deliver/fulltext/aip/journal/rsi/85/11/1.4886455.html;jsessionid=7j1b30f6c0jpb.x-aip-live-02?itemId=/content/aip/journal/rsi/85/11/10.1063/1.4886455&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/rsi
true
true
This is a required field
Please enter a valid email address
This feature is disabled while Scitation upgrades its access control system.
This feature is disabled while Scitation upgrades its access control system.
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Design of vibration compensation interferometer for Experimental Advanced Superconducting Tokamaka)
http://aip.metastore.ingenta.com/content/aip/journal/rsi/85/11/10.1063/1.4886455
10.1063/1.4886455
SEARCH_EXPAND_ITEM