Skip to main content

News about Scitation

In December 2016 Scitation will launch with a new design, enhanced navigation and a much improved user experience.

To ensure a smooth transition, from today, we are temporarily stopping new account registration and single article purchases. If you already have an account you can continue to use the site as normal.

For help or more information please visit our FAQs.

banner image
No data available.
Please log in to see this content.
You have no subscription access to this content.
No metrics data to plot.
The attempt to load metrics for this article has failed.
The attempt to plot a graph for these metrics has failed.
The full text of this article is not currently available.
/content/aip/journal/rsi/85/5/10.1063/1.4873330
1.
1. L. R. Snyder, J. J. Kirkland, and J. L. Glajch, Practical HPLC Method Development (John Wiley and Sons, 2012).
2.
2. B. S. Edwards, T. Oprea, E. R. Prossnitz, and L. A. Sklar, “Flow cytometry for high-throughput, high-content screening,” Curr. Opin. Chem. Biol. 8, 392398 (2004).
http://dx.doi.org/10.1016/j.cbpa.2004.06.007
3.
3. J. W. Lichtman and J.-A. Conchello, “Fluorescence microscopy,” Nat. Methods 2, 910919 (2005).
http://dx.doi.org/10.1038/nmeth817
4.
4. J. R. Lakowicz, Principles of Fluorescence Spectroscopy (Springer, 2007).
5.
5. B. N. G. Giepmans, S. R. Adams, M. H. Ellisman, and R. Y. Tsien, “The fluorescent toolbox for assessing protein location and function,” Science 312, 217224 (2006).
http://dx.doi.org/10.1126/science.1124618
6.
6. M. F. Kircher, R. Weissleder, and L. Josephson, “A Dual fluorochrome probe for imaging proteases,” Bioconjug. Chem. 15, 242248 (2004).
http://dx.doi.org/10.1021/bc034151d
7.
7. A. P. Demchenko, “The concept of λ-ratiometry in fluorescence sensing and imaging,” J. Fluoresc. 20, 10991128 (2010).
http://dx.doi.org/10.1007/s10895-010-0644-y
8.
8. B. Valeur and I. Leray, “Design principles of fluorescent molecular sensors for cation recognition,” Coord. Chem. Rev. 205, 340 (2000).
http://dx.doi.org/10.1016/S0010-8545(00)00246-0
9.
9. R. M. Ballew and J. N. Demas, “An error analysis of the rapid lifetime determination method for the evaluation of single exponential decays,” Anal. Chem. 61, 3033 (1989).
http://dx.doi.org/10.1021/ac00176a007
10.
10. M. Y. Berezin and S. Achilefu, “Fluorescence lifetime measurements and biological imaging,” Chem. Rev. 110, 26412684 (2010).
http://dx.doi.org/10.1021/cr900343z
11.
11. G. Neurauter, I. Klimant, and O. S. Wolfbeis, “Microsecond lifetime-based optical carbon dioxide sensor using luminescence resonance energy transfer,” Anal. Chim. Acta 382, 6775 (1999).
http://dx.doi.org/10.1016/S0003-2670(98)00748-X
12.
12. A. Mills, “Oxygen indicators and intelligent inks for packaging food,” Chem. Soc. Rev. 34, 10031011 (2005).
http://dx.doi.org/10.1039/b503997p
13.
13. W. Zhong, P. Urayama, and M.-A. Mycek, “Imaging fluorescence lifetime modulation of a ruthenium-based dye in living cells: The potential for oxygen sensing,” J. Phys. D: Appl. Phys. 36, 1689 (2003).
http://dx.doi.org/10.1088/0022-3727/36/14/306
14.
14. K. Suhling, D. M. Davis, Z. Petrasek, J. Siegel, and D. Phillips, “Influence of the refractive index on EGFP fluorescence lifetimes in mixtures of water and glycerol,” Biomark. Biol. Spectrom. Imaging 4259, 92101 (2001).
http://dx.doi.org/10.1117/12.432486
15.
15. S. H. Ko, K. Du, and J. A. Liddle, “Quantum-dot fluorescence lifetime engineering with DNA origami constructs,” Angew. Chem., Int. Ed. 52, 11931197 (2013).
http://dx.doi.org/10.1002/anie.201206253
16.
16. P. Haro-González, L. Martínez-Maestro, I. R. Martín, J. García-Solé, and D. Jaque, “High-sensitivity fluorescence lifetime thermal sensing based on CdTe quantum dots,” Small 8, 26522658 (2012).
http://dx.doi.org/10.1002/smll.201102736
17.
17. J. Guo and S. Sonkusale, “A CMOS imager with digital phase readout for fluorescence lifetime imaging,” in Proceedings of the ESSCIRC (ESSCIRC), pp. 115118 (2011).
18.
18. W. Becker, A. Bergmann, K. Koenig, and U. Tirlapur, Picosecond Fluorescence Lifetime Microscopy by TCSPC Imaging (SPIE, 2001), Vol. 4262, pp. 414419.
19.
19. W. Becker et al., High Resolution TCSPC Lifetime Imaging (SPIE, 2003), Vol. 4963, pp. 175184.
20.
20. K. Dowling, S. C. W. Hyde, J. C. Dainty, P. M. W. French, and J. D. Hares, “2D fluorescence lifetime imaging using a time-gated image intensifier,” Opt. Commun. 135, 2731 (1997).
http://dx.doi.org/10.1016/S0030-4018(96)00618-9
21.
21. P. Harms, J. Sipior, N. Ram, G. M. Carter, and G. Rao, “Low cost phase-modulation measurements of nanosecond fluorescence lifetimes using a lock-in amplifier,” Rev. Sci. Instrum. 70, 15351539 (1999).
http://dx.doi.org/10.1063/1.1149620
22.
22. T. Iwata, T. Kamada, and T. Araki, “Phase-modulation fluorometer using an ultraviolet light-emitting diode,” Opt. Rev. 7, 495498 (2000).
http://dx.doi.org/10.1007/s10043-000-0495-x
23.
23. A. G. Ryder, S. Power, T. J. Glynn, and J. J. Morrison, “Time-domain measurement of fluorescence lifetime variation with pH,” Biomark. Biol. Spectrom. Imaging 4259, 102109 (2001).
http://dx.doi.org/10.1117/12.432487
24.
24. C. D. Salthouse, R. Weissleder, and U. Mahmood, “Development of a time domain fluorimeter for fluorescent lifetime multiplexing analysis,” IEEE Trans. Biomed. Circuits Syst. 2, 204211 (2008).
http://dx.doi.org/10.1109/TBCAS.2008.2003195
25.
25. N. C. Shaner, P. A. Steinbach, and R. Y. Tsien, “A guide to choosing fluorescent proteins,” Nat. Methods 2, 905909 (2005).
http://dx.doi.org/10.1038/nmeth819
26.
26. D. Gerion et al., “Synthesis and properties of biocompatible water-soluble silica-coated CdSe/ZnS semiconductor quantum dots,” J. Phys. Chem. B 105, 88618871 (2001).
http://dx.doi.org/10.1021/jp0105488
27.
27. H. Lam, Y. Kostov, G. Rao and L. Tolosa, “A luminescence lifetime assisted ratiometric fluorimeter for biological applications,” Rev. Sci. Instrum. 80, 124302 (2009).
http://dx.doi.org/10.1063/1.3264106
28.
28. J. Kissinger and D. Wilson, “Portable fluorescence lifetime detection for chlorophyll analysis in marine environments,” IEEE Sens. J. 11, 288295 (2011).
http://dx.doi.org/10.1109/JSEN.2010.2054078
29.
29. B. B. Collier and M. J. McShane, “Time-resolved measurements of luminescence,” J. Lumin. 144, 180190 (2013).
http://dx.doi.org/10.1016/j.jlumin.2013.06.034
30.
30.See http://www.iss.com/resources/research/technical_notes/K2CH_FLT.html for Terpetschnig, ISS Technical Notes Fluorescence Lifetime, 2013.
31.
31. M. A. Hines and P. Guyot-Sionnest, “Synthesis and characterization of strongly luminescing ZnS-capped CdSe nanocrystals,” J. Phys. Chem. 100, 468471 (1996).
http://dx.doi.org/10.1021/jp9530562
32.
32. J. Wang, P. Lei, S. T. Andreadis, and T. J. Mountziaris, “Detection of DNA hybridization via fluorescence intensity variations of ZnSe-DNA quantum dot biosensors,” Anal. Lett. 45, 227241 (2012).
http://dx.doi.org/10.1080/00032719.2011.633190
33.
33. J. Wang and T. J. Mountziaris, “Homogeneous immunoassays based on fluorescence emission intensity variations of zinc selenide quantum dot sensors,” Biosens. Bioelectron. 41, 143149 (2013).
http://dx.doi.org/10.1016/j.bios.2012.08.003
34.
34.See supplementary material at http://dx.doi.org/10.1063/1.4873330 for detailed analysis of pulsing circuit and optical properties of ZnSe Qdot based DNA sensors. [Supplementary Material]
35.
35. B. C. Mei et al., “Dilution effects on the photoluminescence of ZnSe quantum-dot dispersions,” Appl. Phys. Lett. 93, 083114083114 (2008).
http://dx.doi.org/10.1063/1.2970995
http://aip.metastore.ingenta.com/content/aip/journal/rsi/85/5/10.1063/1.4873330
Loading
/content/aip/journal/rsi/85/5/10.1063/1.4873330
Loading

Data & Media loading...

Loading

Article metrics loading...

/content/aip/journal/rsi/85/5/10.1063/1.4873330
2014-05-09
2016-12-09

Abstract

Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 M. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.

Loading

Full text loading...

/deliver/fulltext/aip/journal/rsi/85/5/1.4873330.html;jsessionid=jcYBfv-FhV7XaKdtvr96UZ9t.x-aip-live-02?itemId=/content/aip/journal/rsi/85/5/10.1063/1.4873330&mimeType=html&fmt=ahah&containerItemId=content/aip/journal/rsi
true
true

Access Key

  • FFree Content
  • OAOpen Access Content
  • SSubscribed Content
  • TFree Trial Content
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
/content/realmedia?fmt=ahah&adPositionList=
&advertTargetUrl=//oascentral.aip.org/RealMedia/ads/&sitePageValue=rsi.aip.org/85/5/10.1063/1.4873330&pageURL=http://scitation.aip.org/content/aip/journal/rsi/85/5/10.1063/1.4873330'
Right1,Right2,Right3,