Interaction of Iron Tetrasulfophthalocyanine with TiO2 Nanoparticles by XPS
Rent:
Rent this article for
USD
10.1116/11.20051110
/content/avs/journal/sss/15/1/10.1116/11.20051110
http://aip.metastore.ingenta.com/content/avs/journal/sss/15/1/10.1116/11.20051110

Figures

Image of Untitled

Accession#00939–01Host MaterialFePcS on TiO2 nanoparticlesTechniqueXPSSpectral RegionsurveyInstrumentVG Scientific Escalab 200RExcitation SourceAl K α Source Energy1486.6 eVSource Strength240 WSource Sizenot specifiedAnalyzer Typespherical sectorIncident Angle45°Emission AngleAnalyzer Pass Energy:50 eVAnalyzer Resolution1 eVTotal Signal Accumulation Time900 sTotal Elapsed Time1200 sNumber of Scans3Effective Detector Width1 eV

Image of Untitled

Accession#00940–01Host MaterialFePcSTechniqueXPSSpectral RegionsurveyInstrumentVG Scientific Escalab 200RExcitation SourceAl K α Source Energy1486.6 eVSource Strength240 WSource Sizenot specifiedAnalyzer Typespherical sectorIncident Angle45°Emission AngleAnalyzer Pass Energy:50 eVAnalyzer Resolution1 eVTotal Signal Accumulation Time900 sTotal Elapsed Time1200 sNumber of Scans3Effective Detector Width1 eV

Image of Untitled

  • Accession #:00939–02

  • Host Material: FePcS on TiO2 nanoparticles

  • Technique: XPS

  • Spectral Region: O 1s

  • Instrument: VG Scientific Escalab 200R

  • Excitation Source: Al K α

  • Source Energy: 1486.6 eV

  • Source Strength: 240 W

  • Source Size: not specified

  • Analyzer Type: spherical sector

  • Incident Angle: 45°

  • Emission Angle: 0°

  • Analyzer Pass Energy: 50 eV

  • Analyzer Resolution: 1 eV

  • Total Signal Accumulation Time: 120 s

  • Total Elapsed Time: 300 s

  • Number of Scans: 3

  • Effective Detector Width: 0.1 eV

Image of Untitled

  • Accession #:00940–02

  • Host Material: FePcS

  • Technique: XPS

  • Spectral Region: O 1s

  • Instrument: VG Scientific Escalab 200R

  • Excitation Source: Al K α

  • Source Energy: 1486.6 eV

  • Source Strength: 240 W

  • Source Size: not specified

  • Analyzer Type: spherical sector

  • Incident Angle: 45°

  • Emission Angle: 0°

  • Analyzer Pass Energy: 50 eV

  • Analyzer Resolution: 1 eV

  • Total Signal Accumulation Time: 360 s

  • Total Elapsed Time: 660 s

  • Number of Scans: 6

  • Effective Detector Width: 0.1 eV

Image of Untitled

  • Accession #:00939–03

  • Host Material: FePcS on TiO2 nanoparticles

  • Technique: XPS

  • Spectral Region: S 2p

  • Instrument: VG Scientific Escalab 200R

  • Excitation Source: Al K α

  • Source Energy: 1486.6 eV

  • Source Strength: 240 W

  • Source Size: not specified

  • Analyzer Type: spherical sector

  • Incident Angle: 45°

  • Emission Angle: 0°

  • Analyzer Pass Energy: 50 eV

  • Analyzer Resolution: 1 eV

  • Total Signal Accumulation Time: 3000 s

  • Total Elapsed Time: 3300 s

  • Number of Scans: 50

  • Effective Detector Width: 0.1 eV

Image of Untitled

  • Accession #:00940–03

  • Host Material: FePcS

  • Technique: XPS

  • Spectral Region: S 2p

  • Instrument: VG Scientific Escalab 200R

  • Excitation Source: Al K α

  • Source Energy: 1486.6 eV

  • Source Strength: 240 W

  • Source Size: not specified

  • Analyzer Type: spherical sector

  • Incident Angle: 45°

  • Emission Angle: 0°

  • Analyzer Pass Energy: 50 eV

  • Analyzer Resolution: 1 eV

  • Total Signal Accumulation Time: 600 s

  • Total Elapsed Time: 900 s

  • Number of Scans: 10

  • Effective Detector Width: 0.1 eV

Tables

Generic image for table

SPECTRAL FEATURES TABLE

Generic image for table

ANALYZER CALIBRATION TABLE

Generic image for table

GUIDE TO FIGURES

Generic image for table
Generic image for table
Loading

Article metrics loading...

/content/avs/journal/sss/15/1/10.1116/11.20051110
2011-01-21
2014-04-19
Loading

Full text loading...

This is a required field
Please enter a valid email address
752b84549af89a08dbdd7fdb8b9568b5 journal.articlezxybnytfddd
Scitation: Interaction of Iron Tetrasulfophthalocyanine with TiO2 Nanoparticles by XPS
http://aip.metastore.ingenta.com/content/avs/journal/sss/15/1/10.1116/11.20051110
10.1116/11.20051110
SEARCH_EXPAND_ITEM