Using a magnetometer to image a two-dimensional current distribution
J. Appl. Phys. 65, 361 (1989); doi:10.1063/1.342549
Issue Date: 1 January 1989
You are not logged in to this journal. Log in
We describe a mathematical algorithm to obtain an image of a two-dimensional current distribution from measurements of its magnetic field. The spatial resolution of this image is determined by the signal-to-noise ratio of the magnetometer data and the distance between the magnetometer and the plane of the current distribution. In many cases, the quality of the image can be improved more by decreasing the current-to-magnetometer distance than by decreasing the noise in the magnetometer.
Journal of Applied Physics is copyrighted by The American Institute of Physics.
| History: | Received 16 June 1988; accepted 13 September 1988 |
| Permalink: |
http://link.aip.org/link/?JAPIAU/65/361/1 |
KEYWORDS and PACS
- 07.55.+x
Specific instrumentation and techniques of general use in physics Magnetic instruments and techniques - 41.10.Dq
Electricity and magnetism: fields and charged particles Classical electromagnetism Electrostatics, magnetostatics - 87.40.+w
Biophysics, medical physics, and biomedical engineering Biomagnetism (e.g., cardiomagnetism, neuromagnetism, tissue susceptibility) and magnetobiology (e.g., magnetic field effects on cellular processes, and on navigation and behavior of various species) - 02.60.-x
Mathematical methods in physics Numerical approximation and analysis - YEAR: 1988-89
RELATED DATABASES
PUBLICATION DATA
0021-8979 (print)
1089-7550 (online)
REFERENCES (16)
For access to fully linked references, you need to log in.
For access to fully linked references, you need to Log in.
- D. S. Barth, W. Sutherling, J. Engel, Jr., and J. Beatty,
Science 223, 293 (1984 ). - B. J. Roth and J. P. Wikswo, Jr.,
Biophys. J. 48, 93 (1985 ). - B. J. Roth, Ph.D. thesis, Vanderbilt University, 1987 (unpublished).
- J. P. Wikswo, Jr. and B. J. Roth,
Electroencephalogr. Clin. Neurophysiol. 69, 266 (1988 ). - J. D. Jackson, Classical Electrodynamics (Wiley, New York, 1975).
- E. Hecht and A. Zajac, Optics (Addison-Wesley, Reading, MA, 1979).
- I. S. Gradshteyn and I. M. Ryzhik, Table of Integrals, Series and Products (Academic, New York, 1980).
- A. Rosenfeld and A. C. Kak, Digital Picture Processing (Academic, New York, 1982);
- R. H. T. Bates and M. J. McDonnell, Image Restoration and Reconstruction (Clarendon, Oxford, 1986).
- J. W. Goodman, Introduction to Fourier Optics (McGraw-Hill, New York, 1968).
- A. C. Bruno, P. Costa Ribeiro, J. P. von der Weid, and O. G. Symko, J. Appl. Phys. 59, 2584 (1986);
- M. Abramowitz and I. A. Stegun, Handbook of Mathematical Functions (U.S. Department of Commerce, Washington, D.C., 1970).
- G. L. Romani, S. J. Williamson, and L. Kaufman, Rev. Sci. Instrum. 53, 1815 (1982).
- A. V. Oppenheim and R. W. Schafer, Digital Signal Processing (Prentice-Hall, Englewood Cliffs, NJ, 1975).
- J. R. Reitz, F. J. Milford, and R. W. Christy, Foundations of Electromagnetic Theory (Addison-Wesley, Reading, MA, 1980).
- W. J. Dallas,
Appl. Opt. 24, 4543 (1985 ). - W. Kullmann and W. J. Dallas,
IEEE Trans. Biomed. Eng. BME-34, 837 (1987 ).
A. C. Bruno, A. V. Guida, and P. Costa Ribeiro, in Biomagnetism 1987, Proceedings of the 6th International Conference on Biomagnetism, edited by K. Atsumi, M. Kotani, S. Ueno, T. Katila, and S. J. Williamson (Tokyo Denki University Press, Tokyo, Japan, 1988), p. 454.