Changes in Collagen With Aging Maintain Molecular Stability After Overload: Evidence From an In Vitro Tendon Model
Soft tissue injuries are poorly understood at the molecular level. Previous work using differential scanning calorimetry (DSC) has shown that tendon collagen becomes less thermally stable with rupture...

Robust and General Method for Determining Surface Fluid Flow Boundary Conditions in Articular Cartilage Contact Mechanics Modeling

J. Biomech. Eng.  -- March 2010 --  Volume 132,  Issue 3, 031001 (8 pages)
doi:10.1115/1.4000869

You are not logged into the ASME Digital Library.
Log in

Author(s):
Sainath Shrikant Pawaskar, John Fisher, and Zhongmin Jin
Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK
Contact detection in cartilage contact mechanics is an important feature of any analytical or computational modeling investigation when the biphasic nature of cartilage and the corresponding tribology are taken into account. The fluid flow boundary conditions will change based on whether the surface is in contact or not, which will affect the interstitial fluid pressurization. This in turn will increase or decrease the load sustained by the fluid phase, with a direct effect on friction, wear, and lubrication. In laboratory experiments or clinical hemiarthroplasty, when a rigid indenter or metallic prosthesis is used to apply load to the cartilage, there will not be any fluid flow normal to the surface in the contact region due to the impermeable nature of the indenter/prosthesis. In the natural joint, on the other hand, where two cartilage surfaces interact, flow will depend on the pressure difference across the interface. Furthermore, in both these cases, the fluid would flow freely in non-contacting regions. However, it should be pointed out that the contact area is generally unknown in advance in both cases and can only be determined as part of the solution. In the present finite element study, a general and robust algorithm was proposed to decide nodes in contact on the cartilage surface and, accordingly, impose the fluid flow boundary conditions. The algorithm was first tested for a rigid indenter against cartilage model. The algorithm worked well for two-dimensional four-noded and eight-noded axisymmetric element models as well as three-dimensional models. It was then extended to include two cartilages in contact. The results were in excellent agreement with the previous studies reported in the literature.

©2010 American Society of Mechanical Engineers

History: Received 14 November 2008; revised 17 October 2009; posted 21 December 2009; published 3 February 2010
doi: http://dx.doi.org/10.1115/1.4000869

KEYWORDS and PACS

Keywords
PACS
  • 87.19.R-
    Mechanical and electrical properties of tissues and organs (higher organisms)
  • 87.19.rh
    Fluid transport and rheology in tissues and organs (higher organisms)
  • 87.10.Kn
    Finite element calculations (biological/medical physics)
  • YEAR: 2010

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

Coden:
JBENDY
ISSN:
0148-0731 (print)   1528-8951 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (27)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.