Skip navigation.

  ASMEDL.ORG »  Journals »  J. Biomech. Eng. »  Volume 132 »  pp. 34501
Adjust text size: Decrease font size Increase font size

Journal of Biomechanical Engineering
Volume: Page/CID:

Previous Article
Optimization of Inflow Waveform Phase-Difference for Minimized Total Cavopulmonary Power Loss
The Fontan operation is a palliative surgical procedure performed on children, born with congenital heart defects that have yielded only a single functioning ventricle. The total cavo-pulmonary connec...

Deformable Mock Stenotic Artery With a Lipid Pool

J. Biomech. Eng.  -- March 2010 --  Volume 132,  Issue 3, 034501 (4 pages)
doi:10.1115/1.4000937

You are not logged into the ASME Digital Library.
Log in

Author(s):
V. Pazos and R. Mongrain
Department of Mechanical Engineering, McGill University, MacDonald Building, 817 Sherbrooke Street West, Montreal, QC, H3A 2K6, Canada; Research Center, Montreal Heart Institute, 5000 Belanger Est, Montreal, QC, H1T 1C8, Canada

J. C. Tardif
Research Center, Montreal Heart Institute, 5000 Belanger Est, Montreal, QC, H1T 1C8, Canada; Department of Medicine, Université de Montréal, Pavillon Roger-Gaudry, 2900 boul. Edouard Montpetit, Montreal, QC, H3T 1J4, Canada
The comparison, evaluation, and optimization of new techniques, models, or algorithms often require the use of realistic deformable test phantoms. The purpose of this paper is to present a multilayer deformable test specimen mimicking an atherosclerotic coronary artery, suitable for mechanical testing and intravascular imaging. Mock arteries were constructed in three phases using two molds: building a first layer of polyvinyl alcohol (PVA) cryogel, adding a lipid pool and building a second layer of PVA cryogel. To illustrate the deformation of the mock arteries, one has been placed in a custom-made bath, axially stretched then inflated while acquiring intravascular ultrasound (IVUS) images. The resulting specimen presents a progressing lumen narrowing of 25% in cross-sectional area at the peak and a lipid pool. The average inner gel layer is about 0.4 mm thick and the outer about 0.6 mm. The dimensions are of the same order as clinical observations, the first gel layer mimicking the intima-media and the second layer the adventitia. In the sequence of IVUS images, the different components of the mock artery are visible and differentiable. The variation in diameter of the segmented contours is presented for a specific specimen subjected to intraluminal pressure. This double-layer stenotic mock artery is approximately the size of a human coronary artery, has a lipid inclusion, can withstand relative large deformation, suitable for (intravascular) ultrasound imaging, and has customizable geometry and wall material parameters.

©2010 American Society of Mechanical Engineers

History: Received 21 August 2009; revised 12 October 2009; accepted manuscript posted 4 January 2010; published 8 February 2010
doi: http://dx.doi.org/10.1115/1.4000937

KEYWORDS and PACS

Keywords
PACS
  • 87.19.R-
    Mechanical and electrical properties of tissues and organs (higher organisms)
  • 87.63.dh
    Ultrasonographic medical imaging
  • 87.85.G-
    Biomechanics (biomedical engineering)
  • 87.57.nm
    Medical image segmentation
  • 87.57.nf
    Medical image reconstruction
  • 87.16.D-
    Biomembranes, bilayers, and vesicles
  • YEAR: 2010

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

Doc Type:
Technical Brief, Technical Note, Brief Note
Coden:
JBENDY
ISSN:
0148-0731 (print)   1528-8951 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (21)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.