An EMG-Driven Biomechanical Model That Accounts for the Decrease in Moment Generation Capacity During a Dynamic Fatigued Condition
Although it is well known that fatigue can greatly reduce muscle forces, it is not generally included in biomechanical models. The aim of the present study was to develop an electromyographic-driven (...
Next Article
Trans-Thrombus Blood Pressure Effects in Abdominal Aortic Aneurysms
How much and how the thrombus supports the wall of an abdominal aortic aneurysm (AAA) is unclear. While some previous studies have indicated that thrombus lacks the mechanical integrity to support muc...

Particle-Image Velocimetry Study of a Pediatric Ventricular Assist Device

J. Biomech. Eng.  -- July 2010 --  Volume 132,  Issue 7, 071004 (6 pages)
http://dx.doi.org/10.1115/1.4001252

You are not logged into the ASME Digital Library.
Log in

Author(s):
E. Ferrara and M. Muramatsu
Optics Group, Physics Institute, University of São Paulo, São Paulo, SP Brazil

K. T. Christensen
Department of Mechanical Science and Engineering, University of Illinois, Urbana, IL

I. A. Cestari
Department of Bioengineering, Heart Institute, InCor, University of São Paulo Medical School, SP, Brazil
Particle-image velocimetry (PIV) was used to visualize the flow within an optically transparent pediatric ventricular assist device (PVAD) under development in our laboratory. The device studied is a diaphragm type pulsatile pump with an ejection volume of 30 ml per beating cycle intended for temporary cardiac assistance as a bridge to transplantation or recovery in children. Of particular interest was the identification of flow patterns, including regions of stagnation and/or strong turbulence that often promote thrombus formation and hemolysis, which can degrade the usefulness of such devices. For this purpose, phase-locked PIV measurements were performed in planes parallel to the diaphram that drives the flow in the device. The test fluid was seeded with 10  µm polystyrene spheres, and the motion of these particles was used to determine the instantaneous flow velocity distribution in the illumination plane. These measurements revealed that flow velocities up to 1.0 m/s can occur within the PVAD. Phase-averaged velocity fields revealed the fixed vortices that drive the bulk flow within the device, though significant cycle-to-cycle variability was also quite apparent in the instantaneous velocity distributions, most notably during the filling phase. This cycle-to-cycle variability can generate strong turbulence that may contribute to greater hemolysis. Stagnation regions have also been observed between the input and output branches of the prototype, which can increase the likelihood of thrombus formation.

©2010 American Society of Mechanical Engineers

History: Received 28 August 2009; revised 22 January 2010; accepted manuscript posted 11 February 2010; published 18 May 2010
Digital Object Identifier http://dx.doi.org/10.1115/1.4001252

KEYWORDS and PACS

Keywords
PACS
  • 47.63.Cb
    Blood flow in cardiovascular system (fluid dynamics)
  • 87.85.Pq
    Biomedical imaging
  • 87.19.U-
    Haemodynamics
  • 87.85.gf
    Fluid mechanics and rheology (biomechanics in biomedical engineering)
  • YEAR: 2010

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

Coden:
JBENDY
ISSN:
0148-0731 (print)   1528-8951 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (14)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.