Skip navigation.

  ASMEDL.ORG »  Journals »  J. Fuel Cell Sci. Technol. »  Volume 3 »  pp. 99
Adjust text size: Decrease font size Increase font size

Journal of Fuel Cell Science and Technology
Volume: Page/CID:

Previous Article
Analysis of Chemically Reacting Transport Phenomena in an Anode Duct of Intermediate Temperature SOFCs
The internal reforming and electrochemical reactions appear in the porous anode layer, and may lead to inhomogeneous temperature and gas species distributions according to the reaction kinetics. In th...
Next Article
Heat Exchangers for Fuel Cell and Hybrid System Applications
The fuel cell system and fuel cell gas turbine hybrid system represent an emerging technology for power generation because of its higher energy conversion efficiency, extremely low environmental pollu...

Analysis, Modeling, and Validation for the Thermal Dynamics of a Polymer Electrolyte Membrane Fuel Cell System

J. Fuel Cell Sci. Technol.  -- May 2006 --  Volume 3,  Issue 2, 99 (12 pages)
doi:10.1115/1.2173663

You are not logged into the ASME Digital Library.
Log in

Author(s):
Eric A. Müller
Measurement and Control Laboratory, ETH Zentrum, 8092 Zurich, Switzerland

Anna G. Stefanopoulou
Fuel Cell Control Systems Laboratory, The University of Michigan, Ann Arbor, MI 48109
A control-oriented mathematical model of a polymer electrolyte membrane (PEM) fuel cell stack is developed and experimentally verified. The model predicts the bulk fuel cell transient temperature and voltage as a function of the current drawn and the inlet coolant conditions. The model enables thermal control synthesis and optimization and can be used for estimating the transient system performance. Unlike other existing thermal models, it includes the gas supply system, which is assumed to be capable of controlling perfectly the air and hydrogen flows. The fuel cell voltage is calculated quasistatically. Measurement data of a 1.25  kW, 24-cell fuel cell stack with an integrated membrane-type humidification section is used to identify the system parameters and to validate the performance of the simulation model. The predicted thermal response is verified during typical variations in load, coolant flow, and coolant temperature. A first-law control volume analysis is performed to separate the relevant from the negligible contributions to the thermal dynamics and to determine the sensitivity of the energy balance to sensor errors and system parameter deviations.

©2006 American Society of Mechanical Engineers

History: Received 17 March 2005; revised 14 September 2005
doi: http://dx.doi.org/10.1115/1.2173663

KEYWORDS and PACS

Keywords
PACS

PUBLICATION DATA

Coden:
JFCSAU
ISSN:
1550-624X (print)   1551-6989 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (9)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.