Skip navigation.

  ASMEDL.ORG »  Journals »  J. Nanotechnol. Eng. Med. »  Volume 1 »  pp. 31012
Adjust text size: Decrease font size Increase font size

Journal of Nanotechnology in Engineering and Medicine
Volume: Page/CID:

Previous Article
Ordered Au Nanodisk and Nanohole Arrays: Fabrication and Applications
We have utilized nanosphere lithography (NSL) to fabricate ordered Au nanodisk and nanohole arrays on substrates and have studied the localized surface plasmon resonance (LSPR) of the arrays. Through ...
Next Article
Nanoclay Based Composite Scaffolds for Bone Tissue Engineering Applications
Scaffolds based on chitosan/polygalacturonic acid (ChiPgA) complex containing montmorillonite (MMT) clay modified with 5-aminovaleric acid were prepared using freeze-drying technique. The MMT clay was...

Wireless Point-of-Care Diagnosis for Sleep Disorder With Dry Nanowire Electrodes

J. Nanotechnol. Eng. Med.  -- August 2010 --  Volume 1,  Issue 3, 031012 (11 pages)
doi:10.1115/1.4002138

You are not logged into the ASME Digital Library.
Log in

Author(s):
Vijay K. Varadan, 21st Century Endowed Chair in Nano- and Bio-Technologies and Medicine, Distinguished Professor of Electrical Engineering and Biomedical Engineering, Professor of Neurosurgery
University of Arkansas, Fayetteville, AR 72701

Sechang Oh, Hyeokjun Kwon, and Phillip Hankins
Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701
Currently, available sleep monitoring systems use electrical recording where the electrodes make contact with the patient's skin using a conducting gel. The electrode wires are connected to a processing recording system. The subject has to be in close proximity of these machines due to the direct electrical connections with the body and the machine. The conductive gel along with many wires connected to the biopotential electrodes makes them uncomfortable for the subject, with the result that recording and monitoring of the patient's sleep patterns can become very difficult. The patient has to be in a sleep lab and/or a hospital at all times and at least one technician needs to watch the patient's sleep behavior via video. The patient may not experience normal sleep patterns under such environments and as such, the diagnostic results are not really very conclusive. The commonly monitored biopotential electrodes are electrocardiogram, electroencephalogram, electromyogram, and electrooculogram. The electrodes used for monitoring these signals are Ag/AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gel takes a role of reducing skin contact impedance in the conventional Ag/AgCl electrode and its usage is directly related to the sensitivity. However, the wet conventional Ag/AgCl electrode has some drawbacks such as difficulty in long time monitoring because the gel dries out after few hours and skin irritations. Usually, physiological parameters are monitored over an extended period of time during the patient's normal daily life to diagnose a disease. In this case, the wet conventional Ag/AgCl cannot be used because of the dry-out of gel. The dry-out of gel increases the impedance between skin and electrode and it is reflected in the poor signal sensitivity. Also noises, such as motion artifact and baseline wander, are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry nanoelectrodes are proposed in this paper where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The results are presented along with a wireless communication such that the proposed system is ideal for point-of-care diagnosis of the patient at home.

©2010 American Society of Mechanical Engineers

History: Received 25 June 2010; revised 29 June 2010; published 27 August 2010
doi: http://dx.doi.org/10.1115/1.4002138

KEYWORDS and PACS

Keywords
PACS
  • 87.85.Rs
    Nanotechnologies - applications in biomedical engineering
  • 87.85.jj
    Biocompatibility (biomaterials in biomedical engineering)
  • 87.85.D-
    Applied neuroscience in biomedical engineering
  • 87.19.le
    EEG and MEG
  • 87.19.X-
    Diseases
  • YEAR: 2010

PUBLICATION DATA

Coden:
JNEMAA
ISSN:
1949-2944 (print)   1949-2952 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (11)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.