Home SEARCH: Current - All BROWSE: Current - All MyScitation Help Exit

Previous Article
Development of wavy texture in startup flows of liquid crystalline polymer solution through a slit cell
The development of wavy texture in startup flows of liquid crystalline polymers through a slit cell is examined to clarify the mechanism of this phenomenon, using a liquid crystalline solution of 50 w...
Next Article
Nonlinear viscoelastic analysis of the torque, axial normal force and volume change measured simultaneously in the National Institute of Standards and Technology torsional dilatometer
For compressible materials, the mechanical response to a torsional deformation (at sufficiently large levels of deformation) includes the nonlinear effects of a compressive normal force along the axis...

You are not logged in to this journal. Log in

Rheological measurements using microcantilevers

J. Rheol. Volume 46, Issue 4, pp. 891-899 (July 2002)

Issue Date: July 2002
Buy This PDF   (US$28)
Download HTML Download Sectioned HTML Download PDF (76 kB) View Cart

KEYWORDS and PACS

Keywords
PACS
  • 83.85.Cg
    Rheology Techniques and apparatus Rheological measurements—rheometry
  • 83.85.Jn
    Rheology Techniques and apparatus Viscosity measurements
  • 07.79.Lh
    Instruments, apparatus, and components common to several branches of physics and astronomy Scanning probe microscopes and components Atomic force microscopes
  • YEAR: 2002

PUBLICATION DATA

ISSN:
0148-6055 (print)   1520-8516 (online)
Publisher:
AIP is a member of CrossRef SOR
S. Boskovic
Department of Chemical Engineering and School of Chemistry, The University of Melbourne, Victoria, 3010 Australia

J. W. M. Chon and P. Mulvaney
School of Chemistry, The University of Melbourne, Victoria, 3010 Australia

J. E. Sader
Department of Mathematics and Statistics, The University of Melbourne, Victoria, 3010 Australia
The use of microcantilevers in rheological measurements of gases and liquids is demonstrated. Densities and viscosities of both gases and liquids, which can range over several orders of magnitude, are measured simultaneously using a single microcantilever. The microcantilever technique probes only minute volumes of fluid (<1 nL), and enables in situ and rapid rheological measurements. This is in direct contrast to established methods, such as "cone and plate" and Couette rheometry, which are restricted to measurements of liquid viscosity, require large sample volumes, and are incapable of in situ measurements. The proposed technique also overcomes the restrictions of previous measurements that use microcantilevers, which are limited to liquid viscosity only, and require independent measurement of the liquid density. The technique presented here only requires knowledge of the cantilever geometry, its resonant frequency in vacuum, and its linear mass density. A simple yet robust calibration procedure is described to determine the latter two parameters, from a single measurement of the resonant frequency and quality factor of the cantilever in a reference fluid (such as air), if these parameters are unknown. ©2002 The Society of Rheology.
History: Received 11 September 2001; revised 25 February 2002
Permalink: http://dx.doi.org/10.1122/1.1475978

REFERENCES (12)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.


SEARCH: Current - All BROWSE: Current - All MyScitation Help Exit
© Copyright The Society of Rheology