Skip navigation.

  ASMEDL.ORG »  Journals »  J. Turbomach. »  Volume 132 »  pp. 11018
Adjust text size: Decrease font size Increase font size

Journal of Turbomachinery
Volume: Page/CID:

Previous Article
Letterbox Trailing Edge Heat Transfer: Effects of Blowing Rate, Reynolds Number, and External Turbulence on Heat Transfer and Film Cooling Effectiveness
Heat transfer and film cooling distributions have been acquired for a vane trailing edge with letterbox partitions. Additionally, pressure drop data have been experimentally determined across a pin fi...
Next Article
Three Dimensional Clocking Effects in a One and a Half Stage Transonic Turbine
This paper presents an experimental investigation of the flow field in a high-pressure transonic turbine with a downstream vane row (1.5 stage machine) concerning the airfoil indexing. The objective i...

An Experimental Study of Vane Clocking Effects on Embedded Compressor Stage Performance

J. Turbomach.  -- January 2010 --  Volume 132,  Issue 1, 011018 (10 pages)
doi:10.1115/1.3072714

You are not logged into the ASME Digital Library.
Log in

Author(s):
Nicole L. Key, Patrick B. Lawless, and Sanford Fleeter
Purdue University, West Lafayette, IN 47907
Previous research has shown that vane clocking, the circumferential indexing of adjacent vane rows with similar vane counts, can be an effective means to increase stage performance, reduce discrete frequency noise, and/or reduce the unsteady blade forces that can lead to high cycle fatigue. The objective of this research was to experimentally investigate the effects of vane clocking in an embedded compressor stage, focusing on stage performance. Experiments were performed in the intermediate-speed Purdue three-stage compressor, which consists of an IGV followed by three stages. The IGV, Stator 1, and Stator 2 vane rows have identical vane counts, and the effects of vane clocking were studied on Stage 2. Much effort went into refining performance measurements to enable the detection of small changes in stage efficiency associated with vane clocking. At design loading, the change in stage efficiency between the maximum and minimum efficiency clocking configurations was 0.27 points. The maximum efficiency clocking configuration positioned the Stator 1 wake at the Stator 2 leading edge. This condition produced a shallower and thinner Stator 2 wake compared with the clocking configuration that located the wake in the middle of the Stator 2 passage. At high loading, the change in Stage 2 efficiency associated with vane clocking effects increased to 1.07 points; however, the maximum efficiency clocking configuration was the case where the Stator 1 wake passed through the middle of the downstream vane passage. Thus, impingement of the upstream vane wake on the downstream vane leading edge resulted in the best performance at design point but provided the lowest efficiency at an off-design condition.

©2010 American Society of Mechanical Engineers

History: Received 18 September 2008; revised 20 October 2008; published 21 September 2009
doi: http://dx.doi.org/10.1115/1.3072714

KEYWORDS and PACS

Keywords
PACS

PUBLICATION DATA

Coden:
JOTUEI
ISSN:
0889-504X (print)   1528-8900 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (24)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.