Skip navigation.

  ASMEDL.ORG »  Journals »  J. Turbomach. »  Volume 132 »  pp. 21017
Adjust text size: Decrease font size Increase font size

Journal of Turbomachinery
Volume: Page/CID:

Previous Article
Aerothermal Investigation of Tip Leakage Flow in a Film Cooled Industrial Turbine Rotor
A numerical investigation of the flow and heat transfer characteristics of tip leakage in a typical film cooled industrial gas turbine rotor is presented in this paper. The computations were performed...
Next Article
Experiments and Computations on Large Tip Clearance Effects in a Linear Cascade
Large tip clearances typically in the region of 6% exist in the high pressure (HP) stages of compressors of industrial gas turbines. Due to the relatively short annulus height and significant blockage...

Numerical Investigation on the Self-Induced Unsteadiness in Tip Leakage Flow for a Transonic Fan Rotor

J. Turbomach.  -- April 2010 --  Volume 132,  Issue 2, 021017 (9 pages)
doi:10.1115/1.3145103

You are not logged into the ASME Digital Library.
Log in

Author(s):
Juan Du
Graduate School of Chinese Academy of Sciences, Beijing 100190, China; Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China; Key Laboratory of Advanced Energy and Power, IET, CAS, Beijing 100190, China

Feng Lin
Tri-State University, Angola, IN 46703

Hongwu Zhang and Jingyi Chen
Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100080, China; Key Laboratory of Advanced Energy and Power, CAS, Beijing 100080, China
A numerical investigation on the self-induced unsteadiness in tip leakage flow is presented for a transonic fan rotor. NASA Rotor 67 is chosen as the computational model. It is found that under certain conditions the self-induced unsteadiness can be originated from the interaction of two important driving “forces:” the incoming main flow and the tip leakage flow. Among all the simulated cases, the self-induced unsteadiness exists when the size of the tip clearance is equal to or larger than the design tip clearance. The originating mechanism of the unsteadiness is clarified through time-dependent internal flow patterns in the rotor tip region. It is demonstrated that when strong enough, the tip leakage flow impinges the pressure side of neighboring blade and alters the blade loading significantly. The blade loading in turn changes the strength of the tip leakage flow and results in a flow oscillation with a typical signature frequency. This periodic process is further illustrated by the time-space relation between the driving forces. A correlation based on the momentum ratio of tip leakage flow over the incoming main flow at the tip region is used as an indicator for the onset of the self-induced unsteadiness in tip leakage flow. It is discussed that the interaction between shock wave and tip leakage vortex does not initiate the self-induced unsteadiness, but might be the cause of other types of unsteadiness, such as broad-banded turbulence unsteadiness.

©2010 American Society of Mechanical Engineers

History: Received 14 August 2008; revised 23 February 2009; published 20 January 2010
doi: http://dx.doi.org/10.1115/1.3145103

KEYWORDS and PACS

Keywords
PACS
  • 47.20.-k
    Flow instabilities
  • 47.40.Hg
    Transonic flows
  • 47.54.Bd
    Theoretical aspects of pattern selection and formation
  • 47.40.Nm
    Shock-wave interactions and shock effects
  • 47.32.cb
    Vortex interactions
  • 47.85.Gj
    Aerodynamics (applied)
  • YEAR: 2010

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

Coden:
JOTUEI
ISSN:
0889-504X (print)   1528-8900 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (16)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.