Skip navigation.

  ASMEDL.ORG »  Journals »  J. Turbomach. »  Volume 132 »  pp. 21018
Adjust text size: Decrease font size Increase font size

Journal of Turbomachinery
Volume: Page/CID:

Previous Article
Numerical Investigation on the Self-Induced Unsteadiness in Tip Leakage Flow for a Transonic Fan Rotor
A numerical investigation on the self-induced unsteadiness in tip leakage flow is presented for a transonic fan rotor. NASA Rotor 67 is chosen as the computational model. It is found that under certai...
Next Article
Heat Transfer in Radially Rotating Pin-Fin Channel at High Rotation Numbers
Endwall heat transfer measurements for a radially rotating rectangular pin-fin channel with the width-to-height ratio (aspect ratio) of 8 are performed at the parametric conditions of 5000Re20,000, 0R...

Experiments and Computations on Large Tip Clearance Effects in a Linear Cascade

J. Turbomach.  -- April 2010 --  Volume 132,  Issue 2, 021018 (10 pages)
doi:10.1115/1.3104611

You are not logged into the ASME Digital Library.
Log in

Author(s):
Richard Williams, David Gregory-Smith, Li He, and Grant Ingram
University of Durham, South Road, Durham DH1 3LE, UK
Large tip clearances typically in the region of 6% exist in the high pressure (HP) stages of compressors of industrial gas turbines. Due to the relatively short annulus height and significant blockage, the tip clearance flow accounts for the largest proportion of loss in the HP. Therefore increasing the understanding of such flows will allow for improvements in design of such compressors, increasing efficiency, stability, and the operating range. Experimental and computational techniques have been used to increase the physical understanding of the tip clearance flows through varying clearances in a linear cascade of controlled-diffusion blades. This paper shows two unexpected results. First the loss does not increase with clearances greater than 4% and second there is an increase in blade loading toward the tip above 2% clearance. It appears that the loss production mechanisms of the pressure driven tip clearance jet do not increase as the clearance is increased to large values. The increase in blade force is attributed to the effect of the strong tip clearance vortex, which does not move across the blade passage to the pressure surface, as is often observed for high stagger blading. These results may be significant for the design of HP compressors for industrial gas turbines.

©2010 American Society of Mechanical Engineers

History: Received 14 October 2008; revised 18 November 2008; published 20 January 2010
doi: http://dx.doi.org/10.1115/1.3104611

KEYWORDS and PACS

Keywords
PACS

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

Coden:
JOTUEI
ISSN:
0889-504X (print)   1528-8900 (online)
Publisher:
AIP is a member of CrossRef ASME

REFERENCES (18)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.