Next Article
A verification of the Monte Carlo code MCNP for thick target bremsstrahlung calculations
The bremsstrahlung spectra from thick targets of Be, Al, and Pb are calculated using the Monte Carlo code MCNP (Monte Carlo N-particle). The current version of MCNP (v.4A) incorporates a coupled elect...

You are not logged in to this journal. Log in

Reconstruction of 12 MV bremsstrahlung spectra from measured transmission data by direct resolution of the numeric system AF=T

Med. Phys. Volume 22, Issue 1, pp. 3-10 (January 1995)

Issue Date: January 1995
Buy This PDF   (US$25)
Download PDF (608 kB) View Cart

KEYWORDS and PACS

Keywords
PACS
  • 87.53.Dq
    Biophysics and medical physics Ionizing-radiation therapy physics Photon dosimetry: measurements
  • YEAR: 1995

PUBLICATION DATA

ISSN:
0094-2405 (print)  
Publisher:
AIP is a member of CrossRef AAPM
A. Catala, P. Francois, and J. Bonnet
Centre Claudius REGAUD, Unité de Physique, Département de Radiothérapie, 20-24 Rue du Pont St. Pierre, 31052, Toulouse, France

Ch. Scouarnec
Université Paul Sabatier, Laboratoire de Mathématiques Pour les Sciences Physiques, 118 Route de Narbonne, 31062, Toulouse, France
An investigation of x-ray spectral reconstruction from transmission data by direct resolution of the matrix system A*F=T (using spectral algebra formalism) has been previously presented. The resolution has been done with simulated spectrum. In this paper, the method on a real case of a 12 MV photon beam was tested. A special study of the setup has been made to estimate and reduce the experimental errors that could alter the results. In order to convert F(E) (a fraction of the signal due to a photon of energy E) into photon fluence Phi(E), the chamber energy response R(E) has been studied and an approximated analytical function for its representation was proposed. Spectra reconstructed from different transmission data using different attenuators, buildup caps, and ionization chambers have been compared to verify the uniqueness of the reconstructed spectra. To test the validity of the results, dosimetric values, such as Depth Dose Data have been calculated, from our spectrum, using a specific code developed by Kosunen et al. The results show a good agreement between the measured and calculated data.
History: Received 7 April 1994; accepted 20 October 1994
Permalink: http://dx.doi.org/10.1118/1.597523

There are no references.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.