WE-C-ValA-03: The Use of CT Density Changes at Internal Tissue Interfaces to Monitor Respiratory Induced Lung Tumor Motion
Purpose: To describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to apply the method to construct 4D-CT dataset...
Next Article
WE-C-ValA-05: Comparison of Thermocouple and Spirometer for Monitoring Patient Breathing
Purpose: To show the feasibility of using a thermocouple for monitoring patient breathing and to compare its breathing signal with that of a spirometer. Method and Materials: A mask covering the nose-...

You are not logged in to this journal. Log in

WE-C-ValA-04: Derivation of the Tumor Position From External Respiratory Surrogates with Periodical Updating of External/internal Correlation

Med. Phys. Volume 33, Issue 6, pp. 2232-2233 (June 2006)

Issue Date: June 2006
Buy This PDF   (US$28)
Download PDF (4168 kB) View Cart

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

ISSN:
0094-2405 (print)  
Publisher:
AIP is a member of CrossRef AAPM
E Kanoulas,1 J Aslam,1 G Sharp,2 R Berbeco,3,6 S Nishioka,4 H Shirato,5 and S Jiang2
1Northeastern University, Boston, MA
2Massachusetts General Hospital, Boston, MA
3Brigham and Women's Hospital
4Department of Radiology, NTT Hospital, Sapporo, Japan
5Hokkaido University, School of Medicine, Sapporo, Japan
6Harvard Medical School, Boston, MA

Purpose: To develop techniques that can derive the tumor position from external respiratory surrogates through periodically updated internal/external correlation. Method and Materials: A simple linear function is used to express the correlation between tumor and surrogate motion. The function parameters are established during patient setup session with both tumor and surrogate positions measured at 30Hz rate. During treatment, the surrogate position, constantly acquired at 30Hz, is used to derive the tumor position. Occasionally, a tumor image is acquired to enable the updating of the correlation function. Four update methods are investigated. (a) Line shift. (b) Fit model — through point. (c) Fit model — extra weight. (d) Function difference — fit point. Results: Tumor and external surrogate motion demonstrates a high degree of correlation however it dynamically changes over time. Occasionally updating the correlation function leads to more accurate predictions than using external surrogates alone. At the lowest tumor imaging rate tested in this work (0.1Hz) an accuracy improvement of 10% over the prediction by the mere use of external surrogate was observed for the best update method. Update methods (a) and (b) derive the tumor position with larger accuracy than (c) and (d) in case of high imaging rates. The opposite is observed in case of low imaging rates. Conclusion: Occasional calibration of the tumor/external surrogate correlation during treatment substantially increases the accuracy of the tumor localization compared to tumor position derivation by using the external surrogate alone.This work is partially supported by CenSSIS. ©2006 American Association of Physicists in Medicine