Simple ortho-para hydrogen and para-ortho deuterium converter for matrix isolation spectroscopy
A copper tube containing catalyst immersed in the cold gas above liquid helium is used to convert normal H2 and D2 to high purity J = 0 samples. The converted samples are sublimed directly from 12...
Next Article
A three-dimensional electron spin resonance microscope
An electron spin resonance (ESR) imaging system, capable of acquiring three-dimensional (3D) images with a resolution of ~10×10×30  µm in a few minutes of acquisition, is p...

Simple force balance accelerometer/seismometer based on a tuning fork displacement sensor

Rev. Sci. Instrum. 75, 3045 (2004); doi:10.1063/1.1786333

Published 14 September 2004

You are not logged in to this journal. Log in

D. Stuart-Watson and J. Tapson
Department of Electrical Engineering, University of Cape Town, Rondebosch 7701, South Africa
Seismometers and microelectromechanical system accelerometers use the force-balance principle to obtain measurements. In these instruments the displacement of a mass object by an unknown force is sensed using a very high-resolution displacement sensor. The position of the object is then stabilized by applying an equal and opposite force to it. The magnitude of the stabilizing force is easily measured, and is assumed to be equivalent to the unknown force. These systems are critically dependent on the displacement sensor. In this article we use a resonant quartz tuning fork as the sensor. The tuning fork is operated so that its oscillation is lightly damped by the proximity of the movable mass object. Changes in the position of the mass object cause changes in the phase of the fork's resonance; this is used as the feedback variable in controlling the mass position. We have developed an acceleration sensor using this principle. The mass object is a piezoelectric bimorph diaphragm which is anchored around its perimeter, allowing direct electronic control of the displacement of its center. The tuning fork is brought very close to the diaphragm center, and is connected into a self-oscillating feedback circuit which has phase and amplitude as outputs. The diaphragm position is adjusted by a feedback loop, using phase as the feedback variable, to keep it in a constant position with respect to the tuning fork. The measured noise for this sensor is approximately 10.0  mg in a bandwidth of 100  Hz, which is substantially better than commercial systems of equivalent cost and size. ©2004 American Institute of Physics
History: Received 2 April 2004; accepted 16 June 2004; published 14 September 2004
Permalink: http://link.aip.org/link/?RSINAK/75/3045/1
BUY THIS ARTICLE   (US$28)
Download PDF (283 kB) View Cart

KEYWORDS and PACS

Keywords
PACS
  • 07.10.Pz
    Instruments for strain, force, and torque
  • 85.85.+j
    Micro- and nano-electromechanical systems (MEMS/NEMS) and devices
  • 06.30.Gv
    Velocity, acceleration, and rotation measurement
  • 07.07.Df
    Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing
  • 07.10.Cm
    Micromechanical devices and systems
  • YEAR: 2004

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

ISSN:
0034-6748 (print)   1089-7623 (online)
Publisher:
AIP is a member of CrossRef AIP

REFERENCES (9)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.
  1. A. Barzilai, T. VanZandt, T. Pike, S. Manion, and T. Kenny, Conference Proceedings, American Society of Mechanical Engineers International Conference, San Francisco Nov. 1998 (unpublished).
  2. R. D. Grober, J. Acimovic, J. Schuck, D. Hessman, P. Kindlemann, J. Hesphana, S. A. Morse, K. Karrai, I. Tiemann, and S. Manus, Rev. Sci. Instrum. 71, 2776 (2000).
  3. A. G. T. Ruiter, J. A. Veerman, K. O. van der Werf, and N. F. van Hulst, Appl. Phys. Lett. 71, 28 (1997).
  4. V.E. Bottom, Introduction to Quartz Crystal Unit Design (Van Nostrand Reinhold, Toronto, 1982), Chap. 6.
  5. K. Karrai and R. D. Grober, Appl. Phys. Lett. 66, 1842 (1995).
  6. W. H. J. Rensen, N. F. van Hulst, A. G. T. Ruiter, and P. E. West, Appl. Phys. Lett. 75, 1640 (1999).
  7. F. J. Giessibl, Appl. Phys. Lett. 73, 3956 (1998).
  8. M. J. Gregor, P. G. Blome, J. Schöfer, and R. G. Ulbrich, Appl. Phys. Lett. 68, 307 (1996).
  9. J.S. Bendat and A.G. Piersol, Engineering Applications of Correlation and Spectral Analysis. 2nd ed. (Wiley, New York, 1993).

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.