Partially ferromagnetic electromagnet for trapping and cooling neutral atoms to quantum degeneracy
We have developed a compact partially ferromagnetic electromagnet to produce an Ioffe-Pritchard trap for neutral atoms. Our structure permits strong magnetic confinement with low power consumption. Co...
Next Article
Development of a 27.12  MHz radio frequency driven ion source with 3  mTorr operation pressure for neutron generators
An inductively coupled rf plasma ion source has been developed for neutron generators. The ion source configuration has been optimized for low pressure operation. Both 13.56 and 27.12  MHz r...

Technique for increasing dynamic range of space-borne ion composition instruments

Rev. Sci. Instrum. 76, 103301 (2005); doi:10.1063/1.2084867

Published 3 October 2005

You are not logged in to this journal. Log in

J. L. Burch, G. P. Miller, A. De Los Santos, C. J. Pollock, S. E. Pope, P. W. Valek, and D. T. Young
Southwest Research Institute, San Antonio, Texas 78228
The dynamic range of ion composition spectrometers is limited by several factors, including saturation of particle counters and spillover of signals from highly dominant species into channels tuned to minor species. Instruments designed for composition measurements of hot plasmas in space can suffer greatly from both of these problems because of the wide energy range required and the wide disparity in fluxes encountered in various regions of interest. In order to detect minor ions in regions of very weak fluxes, geometry factors need to be as large as possible within the mass and volume resources available. As a result, problems with saturation by the dominant fluxes and spillover to minor-ion channels in plasma regions with intense fluxes become especially acute. This article reports on a technique for solving the dynamic-range problem in the few eV to several keV energy/charge range that is of central importance for space physics research where the dominant ion is of low mass/charge (typically H+), and the minor ions are of higher mass/charge (typically O+). The technique involves employing a radio-frequency modulation of the deflection electric field in the back section of an electrostatic analyzer in a time-of-flight instrument. This technique is shown to reduce H+ counts by a controllable amount of up to factors of 1000 while reducing O+ counts by only a few percent that can be calibrated. ©2005 American Institute of Physics
History: Received 17 May 2005; accepted 22 August 2005; published 3 October 2005
Permalink: http://link.aip.org/link/?RSINAK/76/103301/1
BUY THIS ARTICLE   (US$28)
Download PDF (194 kB) View Cart

KEYWORDS and PACS

Keywords
PACS
  • 07.87.+v
    Spaceborne and space research instruments, apparatus, and components (satellites, space vehicles, etc.)
  • 94.80.+g
    Instrumentation for aeronomy and magnetospheric studies
  • 07.75.+h
    Mass spectrometers
  • 52.70.Nc
    Particle plasma diagnostic measurements
  • 95.30.Qd
    Astrophysical magnetohydrodynamics and plasmas
  • YEAR: 2005

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

ISSN:
0034-6748 (print)   1089-7623 (online)
Publisher:
AIP is a member of CrossRef AIP

REFERENCES (7)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.
  1. T. D. Phan et al., Geophys. Res. Lett.30, 1509 (2003).
  2. H. Reme et al., Ann. Geophys. 19, 1303 (2001).
  3. W. R. Smythe, Phys. Rev. 28, 1275 (1926).
  4. C. W. Carlson, D. W. Curtis, G. Paschmann, and W. Michael, Adv. Space Res. 2, 67 (1982).
  5. D. T. Young et al., Rev. Sci. Instrum. 59, 743 (1988).
  6. S. A. Fuselier et al., J. Geophys. Res. 102, 4847 (1997).
  7. T. D. Phan et al., J. Geophys. Res. 105, 5497 (2000).

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.