Review of Scientific Instruments
Search:
   
 
 
 
Previous Article
Design of a high-temperature and high-pressure liquid flow cell for x-ray absorption fine structure measurements under catalytic reaction conditions
The design and performance of a new high-pressure and high-temperature cell for measurement of x-ray absorption fine structure (XAFS) spectra of solid catalysts working in a flowing liquid are present...
Next Article
Design and construction of a magnetic resonance compatible multi-injector gas jet delivery system
We present the design, construction, and performance of a novel multi-injector gas jet delivery capable of operating in a magnetic resonance imaging environment. This apparatus is computer controlled ...

A Hadamard transform electron ionization time-of-flight mass spectrometer

Rev. Sci. Instrum. 79, 014102 (2008); doi:10.1063/1.2838174

Published 31 January 2008

You are not logged in to this journal. Log in

Jeffrey W. Hudgens and Denis E. Bergeron
National Institute of Standards and Technology, Physical and Chemical Properties Division, 100 Bureau Drive, Stop 8380, Gaithersburg, Maryland 20899-8380, USA
We describe the first Hadamard transform time-of-flight mass spectrometer (HT-TOFMS) that incorporates an electron (impact) ionization source. This implementation was realized in an existent TOF instrument using commercially available components and simple modifications to the ion source. In the present apparatus, a Hadamard mask is expressed by modulating the ion generation process within the ion source; thus, the present approach differs from previous designs that use external electrostatic devices to modulate a continuous ion stream. The present implementation may be operated in conventional TOF mode at 12.5  kHz and in HT-TOF mode at 20–40  MHz. In Hadamard mode the design can operate using any circulant simplex code, allowing the operator much flexibility for optimizing resolution and mass range and for eliminating nonstochastic fluctuations, e.g., encoding errors and signal hum. We demonstrate typical performance of the HT-TOFMS in standard and reflectron geometries using sequences of three constructions and of varied length, generating HT-TOF mass spectra of molecules that match conventional reference spectra. The auxiliary material includes an electrical schematic for the floating high-speed encoding amplifier, which is also of use in other high-speed electrostatic optics applications, and a list of 537 validated vectors comprising the first row of each circulant simplex sequence (Sn=3–8219) derived using maximal shift register (n=2m−1), quadratic residue (n=4m−3), and twin prime constructions [n=p(p+2)]. ©2008 American Institute of Physics
History: Received 7 November 2007; accepted 1 January 2008; published 31 January 2008
Permalink: http://link.aip.org/link/?RSINAK/79/014102/1
BUY THIS ARTICLE   (US$24)
Download PDF (407 kB) View Cart

EPAPS

KEYWORDS and PACS

Keywords
PACS
  • 02.30.Uu
    Integral transforms
  • 32.10.Bi
    Atomic masses, mass spectra, abundances, and isotopes
  • 34.80.Dp
    Atomic excitation and ionization by electron/positron impact
  • YEAR: 2008

RELATED DATABASES


To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.

PUBLICATION DATA

ISSN:
0034-6748 (print)   1089-7623 (online)
Publisher:
AIP is a member of CrossRef AIP

REFERENCES (42)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.
  1. A. Brock, N. Rodriguez, and R. N. Zare, Anal. Chem. 70, 3735 (1998).
  2. A. Brock, N. Rodriguez, and R. N. Zare, Rev. Sci. Instrum. 71, 1306 (2000).
  3. F. M. Fernandez, J. M. Vadillo, F. Engelke, J. R. Kimmel, R. N. Zare, N. Rodriguez, M. Wetterhall, and K. Markides, J. Am. Soc. Mass Spectrom. 12, 1302 (2001).
  4. R. N. Zare, F. M. Fernandez, and J. R. Kimmel, Angew. Chem., Int. Ed. 42, 30 (2003).
  5. J. R. Kimmel, F. M. Fernandez, and R. N. Zare, J. Am. Soc. Mass Spectrom. 14, 278 (2003).
  6. J. R. Kimmel, O. K. Yoon, I. A. Zuleta, O. Trapp, and R. N. Zare, J. Am. Soc. Mass Spectrom. 16, 1117 (2005).
  7. F. M. Fernandez, J. M. Vadillo, J. R. Kimmel, M. Wetterhall, K. Markides, N. Rodriguez, and R. N. Zare, Anal. Chem. 74, 1611 (2002).
  8. O. K. Yoon, I. A. Zuleta, J. R. Kimmel, M. D. Robbins, and R. N. Zare, J. Am. Soc. Mass Spectrom. 16, 1888 (2005).
  9. T. Kaneta, Y. Yamaguchi, and T. Imasaka, Anal. Chem. 71, 5444 (1999).
  10. T. Kaneta, Anal. Chem. 73, 540A (2001).
  11. T. Kaneta, K. Kosai, and T. Imasaka, Anal. Chem. 74, 2257 (2002).
  12. T. Kaneta, K. Kosai, and T. Imasaka, Anal. Sci. 19, 1659 (2003).
  13. J. A. McReynolds and S. A. Shippy, Anal. Chem. 76, 3214 (2004).
  14. J. A. McReynolds, L. Y. Gao, J. Barber-Singh, and S. A. Shippy, J. Sep. Sci. 28, 128 (2005).
  15. K. Hata, T. Kaneta, and T. Imasaka, Anal. Chim. Acta 556, 178 (2006).
  16. K. L. Braun, S. Hapuarachchi, F. M. Fernandez, and C. A. Aspinwall, Anal. Chem. 78, 1628 (2006).
  17. K. L. Braun, S. Hapuarachchi, F. M. Fernandez, and C. A. Aspinwall, Electrophoresis 28, 3115 (2007).
  18. R. Guchardi and M. A. Schwarz, Electrophoresis 26, 3151 (2005).
  19. B. H. Clowers, W. F. Siems, H. H. Hill, and S. M. Massick, Anal. Chem. 78, 44 (2006).
  20. A. W. Szumlas, S. J. Ray, and G. M. Hieftje, Anal. Chem. 78, 4474 (2006).
  21. M. D. Harwit and N. J. Sloane, Hadamard Transform Optics (Academic, London, 1979).
  22. The term circulant denotes a matrix for which all rows contain the same numeric sequence, except that the elements of each successive row are shifted one column to the left (or right) and the overflowing matrix element fills the vacated column element. See Ref. 21.
  23. The older term, electron impact ionization, has been superseded by the term, electron ionization, which more accurately describes physics leading to ion formation. See P. Price, J. Am. Soc. Mass Spectrom. 2, 336 (1991);
  24. O. D. Sparkman, Mass Spectrometry Desk Reference, 2nd ed. (Global View, Pittsburgh, 2006).
  25. J. R. Kimmel, F. Engelke, and R. N. Zare, Rev. Sci. Instrum. 72, 4354 (2001).
  26. See EPAPS Document No.E-RSINAK-79-019802 for Fig. 1, the circuit diagram for the floating, high-speed amplifier used in the present HT-TOFMS, and Table I, a list of 537 circulant simplex matrixes, Sn, of order n=3–8219. This document can be reached through a direct link in the online article's HTML reference section or via the EPAPS homepage (http://www.aip.org/pubservs/epaps.html). [EPAPS]
  27. Q. S. Hanley, Appl. Spectrosc. 55, 318 (2001).
  28. Q. S. Hanley, Appl. Spectrosc. 57, 1305 (2003).
  29. Certain commercial materials and equipment are identified in this paper in order to adequately specify the experimental procedure. Such identification neither implies recommendation nor endorsement by the National Institute of Standards and Technology nor does it imply that the material or equipment identified is the best available for the purpose.
  30. W. C. Wiley and I. H. McLaren, Rev. Sci. Instrum. 26, 1150 (1955).
  31. B. A. Mamyrin, Int. J. Mass. Spectrom. 206, 251 (2001).
  32. B. A. Mamyrin, V. I. Karataev, D. V. Shmikk, and V. A. Zagulin, Sov. Phys. JETP 37, 45 (1973).
  33. This configuration is considered unconventional due to the grid placement. In this tetrode arrangement, the collector grid (aka space-charge grid) reduces space-charge and increases transconductance. In conventional tetrode tubes the collector grid is not present and a screen grid, residing between the control grid and anode, is biased to eliminate the possibility of self-excited oscillation. See E. D. McArthur, Electronics and Electron Tubes (Wiley, London, 1936).
  34. J. W. Gewartowski and H. A. Watson, Principles of Electron Tubes (D. Van Nostrand, Princeton, 1965).
  35. J. F. Rider, Inside the Vacuum Tube (John F. Rider, New York, 1945).
  36. E. V. Moskovets, Appl. Phys. B: Photophys. Laser Chem.54, 556 (1992).
  37. J. R. Stairs, K. M. Davis, and A. W. Castleman, Jr., J. Chem. Phys. 117, 4371 (2002).
  38. I. Heng and C. H. Cooke, Appl. Math. Lett. 11, 77 (1998).
  39. N. J. A. Sloane, M. Harwit, and M. H. Tai, Appl. Opt. 17, 2991 (1978).
  40. J. D. Tate, J. V. Paukstelis, R. M. Hammaker, and W. G. Fateley, J. Mol. Struct. 300, 385 (1993).
  41. M. H. Tai, M. Harwit, and N. J. A. Sloane, Appl. Opt. 14, 2678 (1975).
  42. M. H. Tai, D. A. Briotta, N. S. Kamath, and M. Harwit, Appl. Opt. 14, 2533 (1975).
  43. S. E. Stein, in NIST Chemistry WebBook, NIST Standard Reference Database Number 69, edited by P. J. Linstrom and W. G. Mallard (National Institute of Standards and Technology, Gaithersburg, 2005).

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.