Home | About Journal | Web Links | E-mail Alerts | RSS RSS Icon | Browse
Previous Article Next Article

The diagnostic capability of x-ray scattering parameters for the characterization of breast cancer

Source: Med. Phys. 37, 4257 (2010); doi:10.1118/1.3465046

Published 22 July 2010

KEYWORDS and PACS
Keywords
PACS
  • 87.64.Bx
    Electron, neutron and X-ray diffraction and scattering in biophysics and medical physics
  • 87.19.xj
    Cancer
  • YEAR: 2010
RELATED DATABASES

To view database links for this article,
you need to log in.
To view database links for this article,
you need to log in.
PUBLICATION DATA
ISSN:
1553-9628 (online)
Publisher:
AIP is a member of CrossRef AAPM
Wael M. Elshemey
Department of Biophysics, Faculty of Science, Cairo University, Giza 12613, Egypt

Omar S. Desouky
Department of Radiation Physics, National Centre for Radiation Research and Technology, Madinet Nasr 13759, Egypt

Mostafa M. Fekry
Department of Biophysics, Faculty of Science, Cairo University, Giza 12613, Egypt

Sahar M. Talaat
Department of Pathology, Faculty of Medicine, Cairo University, Cairo 11559, Egypt

Anwar A. Elsayed
Department of Biophysics, Faculty of Science, Cairo University, Giza 12613, Egypt
Purpose: The evaluation of the diagnostic capability of easy to measure x-ray scattering profile characterization parameters for the detection of breast cancer in excised samples. The selected parameters are the full width at half maximum (FWHM) and area under the x-ray scattering profile of breast tissue in addition to the ratio of scattering intensities (I2/I1%) at 1.6  nm−1 to that at 1.1  nm−1 (corresponding to scattering from soft and adipose tissues, respectively).Methods: A histopathologist is asked to classify 36 excised breast tissue samples into healthy or malignant. A conventional x-ray diffractometer is used to acquire the scattering profiles of the investigated samples. The values of three profile characterization parameters are calculated and the diagnostic capability of each is evaluated by determining the optimal cutoffs of scatter diagrams, calculating the diagnostic indices, and plotting the receiver operating characteristic (ROC) curves.Results: At the calculated optimal cutoff for each of the examined parameters, the sensitivity ranged from 78% (for area under curve) up to 94% (for FWHM), the specificity ranged from 94% [for I2/I1% and area under curve] up to 100% (for FWHM), and the diagnostic accuracy ranged from 86% (for area under curve) up to 97% (for FWHM). The area under the ROC curves is greater than 0.95 for all of the investigated parameters, reflecting a highly accurate diagnostic performance.Conclusions: The discussed tests offered a means to quantitatively evaluate the performance of the suggested breast tissue x-ray scattering characterization parameters. The performance results are promising, indicating that the evaluated parameters would be considered a tool for fast, on spot probing of breast cancer in excised tissue samples. ©2010 American Association of Physicists in Medicine
History: Received 23 March 2010; revised 24 June 2010; accepted 29 June 2010; published 22 July 2010
Permalink: http://dx.doi.org/10.1118/1.3465046

REFERENCES (34)

For access to fully linked references, you need to log in. For access to fully linked references, you need to Log in.

CITING ARTICLES

For access to citing articles, you need to log in.
For access to citing articles, you need to Log in.
ADVERTISEMENT