The descriptions of the new products listed in this
section are based on information supplied to us by the manufacturers. PHYSICS TODAY can assume
no responsibility for their accuracy. To facilitate inquiries about a particular product, a Reader
Service Card is attached inside the back cover of the magazine. Lawrence G. Rubin
June 2005, page 69
Capacitance-Sensing Chip
EtherTouch has developed the AD7103,
a 40-pin ASIC (application-specific integrated circuit) that incorporates the company's e–
field-capacitance-sensing chip technology and is designed to sense presence or absence of motion
and thus track the movement of any object or material at substantial distances. The con_1figuration
features three discrete channels with four selectable inputs. The 12 independent inputs are all
at virtual ground. With 16-bit resolution, the chip provides measurement down to 4attofarads
per root Hz, and thus enables detection of very small movements and/or changes even in the presence
of large background signals. In addition to its capacitive sensor, the AD7103 includes an oscillator,
an A/D converter, and a serial interface. The device is adjustable in frequency, amplitude, phase,
and gain. EtherTouch, 25 Commerce Drive, Cranford, NJ 07016, http://www.ethertouch.com
Fiberoptic Gyroscope Transceiver
Phasebridge has introduced the PB3030,
a three-axis fiberoptic gyroscope (FOG) transceiver that transmits more than 1 mW of output power
with greater than 20 dB of polarization extinction. The FOG transceiver provides more than 30 nm
of optical spectrum and an operating temperature range between –40°C and +85°C.
Ideal for the extreme temperature, shock, and vibration specifications required for aerospace
and munitions guidance, the PB3030 will enable precision inertial guidance in applications where
size and cost are important. The FOG transceiver advantageously competes with MEMS-based gyros
or global positioning systems. The company offers FOG transceivers in single- and three-axis
versions. Phasebridge Inc, 859 South Raymond Avenue, Pasadena, CA 91105, http://www.phasebridge.com
Platinum Resistance Thermometer
Hart Scientific has announced the model
5624, a 10-ohm secondary platinum resistance thermometer (PRT) that is designed to serve as a calibration
standard for high-temperature resistance-temperature detectors and thermocouples. It offers
an accuracy, including short-term stability and calibration uncertainty, of 55 mK over the temperature
range 0°C–962°C. After one year of use, the 5624 drifts less than 10 mK at 0°C.
A uniquely small sensor construction creates low immersion requirements that allow the new PRT
to be used as a reference standard in 6-inch dry-well calibrators and furnaces. The 5624 includes
a NIST-traceable fixed-point calibration that is accredited by the NVLAP (National Voluntary
Laboratory Accreditation Program). Hart Scientific, 799 East Utah Valley Drive, American
Fork, UT 84003-9775, http://www.hartscientific.com
Magnetostrictive Position Sensor
The Temposonics C-series from MTS Systems
is a linear-position sensor that incorporates the company's magnetostrictive sensor technology.
The C-series sensor electronics use application-specific integrated circuits to perform the
necessary signal sensing, control, and analysis. The resulting product fits inside a 36-mm-long
by 23-mm-o.d. cylindrical package. The new sensor's modular architecture allows users to integrate
the sensor into their specific product packaging. For example, although the C-series core sensor
is normally powered by a standard 5-V power supply, the modular architecture can provide a second
electronics board that conFigures the sensor to operate with 12- or 24-V power and also adds protection
circuitry for EMI immunity. The C-series sensor has a 0–5 VDC or pulse-width-modulation
output. MTS Systems Corporation, 3001 Sheldon Drive, Cary, NC 27513, http://www.mtssensors.com
Capacitance-to-Digital Converter
Analog Devices has released the AD7745
family of chips for capacitance-to-digital conversion that combine advanced signal processing
techniques with high levels of integration. The chips feature a 24-bit Sigma-Delta architecture
that provides 20-attofarad resolution and a noise of 5aF per root Hz, and they are tolerant of ground
capacitance and ground leakage currents. The new chips include a temperature sensor, an integrated
clock, a reference, and a multiplexer; no external components are required. The AD7745 and 7746
are two-electrode devices that provide an interface with dual-electrode capacitance sensors;
the 7746 offers two capacitance channels; the AD7747 is a single-electrode chip. The chips operate
at 2.7–5.25 V and 1 mA maximum current. Analog Devices Inc, One Technology Way, P.O. Box
9106, Norwood, MA 02062-9106, http://www.analog.com
Laser Displacement Sensor
The Li-CCD (linearized CCD) from Keyence
America offers noncontact laser distance measurement based on triangulation: The position of
the reflected light on the Li-CCD moves as the position of the target changes. The target's displacement
is measured by detecting this change. The new sensor includes the company's Ernostar lens for high
accuracy and high stability, and uses an active balanced laser engine to control the laser emission
time, laser power, and CCD amplification factor. Specifications include a sampling rate of 50
kHz, a linearity of ±0.03%
of full scale, and a resolution of 4 ×
10–7 inch. The sensor's two-way optical system is available in a wide-spot
type and in a small-spot type that is suitable for minute targets and profile measurements. Keyence
Corporation of America, 50 Tice Boulevard, Woodcliff Lake, NJ 07677, http://www.keyence.com
Hall-Effect Sensor
Allegro Microsystems has introduced
the A3245, an omnipolar, chopper-stabilized, Hall-effect device suited for operation at 3.6–24
V. The omnipolar feature of the new digital switch allows for replacement of reed switches while
eliminating the need for signal conditioning. In addition, magnet orientation is not required
for simple position-sensing applications. The sensor can operate with either a north or south
pole of sufficient strength turning the output on, and in the absence of a magnetic field, the output
is off. The new chip includes a Hall-voltage generator, small-signal amplifier, chopper stabilization,
Schmitt trigger, voltage regulator, and short circuit-protected open-drain output. It is rated
for operation over a temperature range of –40°C to +150°C.
Allegro Microsystems Inc, 115 Northeast Cutoff, Worcester, MA 01606, http://www.allegromicro.com
Gas Monitor
MKS Instruments has developed the Cirrus
system for atmospheric-pressure on-line monitoring and analysis of gases and gas mixtures. It
is ideal for use in fuel-cell gas-analysis applications including studies associated with the
selection and optimization of catalysts used in fuel-cell construction. At the core of the Cirrus
system is a quadrupole mass spectrometer that incorporates a closed ion source, a triple-mass
filter, and a Faraday and secondary electron multiplier detector system. Use of the quadrupole
analyzer enables monitoring of multiple gases at the same time over a dynamic range from ppb to percentage
levels. A silica capillary inlet provides rapid response, while an inert chamber and automated
bake-out and heating capability ensure low background contamination and prevent condensation
during measurement. MKS Instruments Inc, 90 Industrial Way, Wilmington, MA 01887-4610, http://www.mksinst.com
Gas Flow Calibrators
Sierra Instruments' Cal=Trak primary
standard gas flow calibrators are characterized by the most basic of quantities: time and distance.
The dimension-based primary accuracy is reportedly superior to pressure-based secondary methods
and is backed by a rigorous uncertainty analysis. Both models contain a nearly frictionless graphite
piston that moves freely inside a borosilicate glass tube. The model SL-500 series offers an accuracy
of ±0.35%
of mass-flow reading, while the SL-800 (the taller one in the photograph) produces ±0.15%.
Each model of the Cal=Trak allows three interchangeable flow cells to cover the range 5sccm (standard
cubic centimeters per minute) to 50slpm (standard liters per minute). Flow readings are given
in 1–15 s, depending on flow. Sierra Instruments Inc, 5 Harris Court, Building L, Monterey,
CA 93940, http://www.sierrainstruments.com
CCD Area Image Sensor
Hamamatsu has released the S9736 series
of full frame transfer-CCD area image sensors designed for low-light-level applications. The
devices use a multipinned phase mode of operation to achieve a dark current of typically 10e–/pixels
per second at 0°C and a typical readout noise of 4e– rms that enable a very
low-light-level detection and long integration time; this results in a wide dynamic range of about
75 000. Covering a spectral response range of 400–1100 nm, the S9736 series sensors
achieve a quantum efficiency of 39% at 660 nm. The new CCD area image sensors feature a 512 ×
512 pixel format with a pixel size of 24 µm
× 24 µm
and a 100% fill factor; they have an active area of 12.288 mm ×
12.288 mm. The series is available in three different packages: 24-pin ceramic, 28-pin metal,
or plate. All packages include a four-stage thermoelectric-cooled element. Hamamatsu Corporation,
360 Foothill Road, P.O. Box 6910, Bridgewater, NJ 08007-0910, http://www.hamamatsu.com
Surface Pressure Microphone
The Vibration Division of PCB Piezotronics
has announced the addition of model 130A40, a quarter-inch pressure-type microphone, to its line
of acoustic products. The distinguishing feature of this surface microphone is that it is only
6.9 mm in height. It can be laid flat on its 51-mm-o.d. rubber pad or mounted by adhesive for automotive,
aeronautical, and general acoustic, sound pressure level testing. The 130A40 has a sensitivity
rating of 45 mV/Pa and a 20-Hz to 15-kHz frequency range (–2/+5dB).
The prepolarized design of the new microphone enables savings in power supplies and cablesfor
polarizing the transducerand operates from the same power required for ICP accelerometers
in the same test with the same signal conditioning. PCB Piezotronics Inc, 3425 Walden Avenue,
Depew, NY 14043-2495, http://www.pcb.com
Wireless Data Logger for Education
Fourier Systems has introduced the TriLink
wireless data logger, which incorporates Bluetooth technology. The data logger has a sampling
resolution of 12 bits, a sampling rate up to 20 800 samples/s, and up to 256 000 memory
cells. The instrument enables simultaneous sampling of up to 8 sensors from a choice of more than
50 that cover almost the complete science curriculum throughout students' academic careers.
TriLink comes with the company's curriculum packs, catering to middle and high schools across
the physics, chemistry, and biology education programs. Wireless experimentation means that
students are no longer tied to their PCs. Now, science laboratory computers can be positioned far
away from "wet" experiments while still logging the data. Fourier Systems Inc, 9635 Huntcliff
Trace, Atlanta, GA 30350-2615, http://www.fourier-sys.com
Light-Scattering Detector
Wyatt Technology has launched the DAWN
HELEOS multiangle light-scattering detector for use in macromolecular characterization instrumentation.
The new detector can incorporate both multiangle and quasi-elastic light scattering into a single
unit. The DAWN HELEOS is said to be the only light-scattering detector available that can achieve
a dynamic range of 126 dB, which enables the instrument to virtually never go off scale; that results
in faster sample runs and a wider range of sample concentrations than before. The instrument also
uses a 24-bit A/D measurement system with separate A/D converters for each detector channel. That
feature provides the same high sensitivity over the entire range of scattering intensities and
thus makes post-detector amplifiers unnecessary. Wyatt Technology Corporation, 6300 Hollister
Avenue, Santa Barbara, CA 93117-3253, http://www.wyatt.com
Sampling Air Monitor
The UV Hound from Ocean Optics is a point-sampling
air monitor that can simultaneously detect, quantify, and identify up to 20 toxic airborne compounds
at concentrations as low as ppb. The UV Hound works by drawing in ambient air, passing it through
an optical analysis chamber, analyzing it using a UV absorbance method, and then expelling it.
The chamber incorporates the company's HR2000 high-resolution spectrometer that instantly
resolves the fine spectral features of hazardous toxics. Microsoft Windows-based software allows
for compound selection, continuous automated monitoring display, and data logging of targeted
gas concentration. The system can be verified using optional gas calibration standards. Ocean
Optics Inc, 830 Douglas Avenue, Dunedin, FL 34698, http://www.oceanoptics.com
On the Web
ControlSoft offers a free download of
its expanded PID Loop Tuning Tips Pocket Guide that includes both open- and closed-loop
tuning procedures. In addition to the original reference material on common controllers, the
guide now has information on the Siemens S7 and Foxboro IA controllers. ControlSoft Inc, 5387
Avion Park Drive, Highland Heights, OH 44143, http://www.controlsoft.com
New Literature
The National Instruments 2005 catalog
is a virtual instrumentation resource that provides views of technical documents, evaluation
software, and example programs. It includes new product information, comparison charts, and
key specifications. National Instruments Corporation, 11500 North Mopac Expressway, Austin,
TX 78759-3504, http://www.ni.com
Xenon Corp has published a new 26-page
booklet, Sterilization and Decontamination, that describes pulsed UV treatments, said
to be 100 000 times more intense than the Sun, to inactivate microorganisms at a DNA level,
with universal lethality. Xenon Corporation, 20 Commerce Way, Woburn, MA 01801, http://www.xenoncorp.com