The
descriptions of the new products listed in this section are based on information supplied
to us by the manufacturers. PHYSICS TODAY can assume no responsibility for their accuracy. For
more information about a particular product, visit the website at the end of the product description.
Lawrence G. Rubin
June 2006, page 72
Digital pyrodetector
PerkinElmer has announced the DigiPyro,
PYD 1998, a digital pyroelectric IR sensor for home and industrial motion-detection applications.
The device combines a ceramic dual-element con_1figuration with an integrated 14-bit A/D converter,
an internal clock, and a control unit. The company's move from analog to digital technology has
enabled the PYD 1998 to offer several advantages, including space savings from fewer components
and significantly improved electromagnetic interference immunity. In addition, the power supply
rejection ratio is increased by about 30 dB. The detector has a field of view of about 120°,
typical responsivity of almost 4 kV/W, maximum noise of 50 µV
peak-to-peak, and automatic out-of-range correction. Its fast response time allows easy bandpass
management. PerkinElmer Optoelectronics Inc, 44370 Christy Street, Fremont, CA 94538-3180,
http://www.perkinelmer.com
MEMS microphone
Akustica has introduced the AKU2000,
a complementary metal-oxide-semiconductor MEMS single-chip microphone. The surface-mountable
digital-output microphone integrates an acoustic transducer, analog-output amplifier, and
fourth-order sigma-delta modulator. It provides a pulse-density-modulated single-bit digital
output stream that is insensitive to RF and electromagnetic interference. This allows the AKU2000
to be placed in the optimal acoustic location in the device without regard for shielded cabling
or complex signal routing. The new chip is ideal for use in microphone-array applications in which
multiple microphones will be used together to perform noise cancellation or beam forming. Suitable
for portable applications, the AKU2000 supports an input clock frequency of 1–4 MHz and
operates from 2.8 to 3.6 V at less than 750 µA.
Akustica Inc, 2835 East Carson Street, Suite 301, Pittsburgh, PA 15203, http://www.akustica.com
Signal-conditioning boards
Two new expansion boards, MSXB 066 and
MSXB 067, from Microstar Laboratories offer analog signal conditioning for strain gauges, load
cells, resistance temperature detectors, and other resistive sensors. The boards provide a flexible
interface for quarter-bridge, half-bridge, and full-bridge sensors and support eight sensors
per board, force/sense feedback, and sense voltage measurement. Each board has eight differential
inputs, simultaneous sampling, selectable gains, and selectable differential voltage excitation.
The MSXB 067 includes a fourth-order antialias filter for each channel, with a choice of cutoff
frequencies. Applications that require accurate interchannel phase measurements can benefit
from the capability of the new boards to eliminate the phase error that sequential sampling introduces.
Microstar Laboratories Inc, 2265 116th Avenue NE, Bellevue, WA 98004, http://www.mstarlabs.com
IR temperature sensor
Exergen Corp has combined its microIRt/c
IR noncontact temperature sensor with the SmartIRt/c microprocessor platform to enable precision
in small places without problems from leakage current or cold-junction compensation. The Smart
processor continuously monitors and adjusts the complete measuring system. While performing
the complex algorithms that determine the output, it also calibrates itself every second, eliminating
drift or sudden changes. It is programmed to automatically shift expected emissivity by 3% for
every 100 °C increase in target temperature, and thus improve accuracy. The new Smart-microIRt/c
has four sensor heads to choose from, with different fields of view. Four temperature ranges are
available: 0–500 °C, 0–250 °C, 0–100 °C, and –30 to
70 °C. Exergen Corporation, Industrial Division, 400 Pleasant Street, Watertown, MA
02472, http://www.exergen.com
Wireless sensor system
Moteiv Corp's Tmote Invent is a wireless
sensor system designed for industrial applications such as building monitoring and security
control. The package's hardware component includes the company's FCC-certified Tmote Sky sensing
module for communication and computation, with an integrated suite of sensors for light, temperature,
vibration (two-axis accelerometer), and sound (microphone). It also has a rechargeable battery
that charges through any standard USB port, a speaker for auditory feedback, a headphone jack for
discrete applications, and LEDs for visual feedback. The system's software component is Moteiv's
Boomerang open-source TinyOS operating system that features reliable mesh networking and extensive
sensing libraries and can operate with any existing TinyOS installation. Moteiv Corporation,
55 Hawthorne Street, Suite 550, San Francisco, CA 94105, http://www.moteiv.com
Flat-panel x-ray sensor
Hamamatsu Corp has developed the C10013SK,
a new flat-panel x-ray sensor that offers superior image quality for nondestructive inspection
of microelectronic components and other applications and is compatible with energy ranges from
20 to 150 kVp. The C10013SK features an active pixel sensor with an area of 52.8 mm ×
52.8 mm, with each pixel measuring 50 µm
× 50 µm.
The sensor captures 1-megapixel images at a resolution of eight line pairs per mm and exhibits a
readout noise of 80 electrons, said to be a significantly lower level than that of most digital x-ray
sensors. The device consists of a sensor board and a control board. Each pixel has a low-noise amplifier;
the video signal is sent to the output through a correlated double sampling circuit. The control
board converts the analog video signal into a 12-bit digital signal. Hamamatsu Corporation,
360 Foothill Road, P.O. Box 6910, Bridgewater, NJ 08807-0910, http://www.hamamatsu.com
Digital signal conditioner
Electro Standards Laboratories has
announced the model 4336 CellMite Quad AC/DC four-channel digital signal conditioner with 24-bit
internal resolution. It connects directly to two AC LVDT (linear variable-differential transformer)
transducers and two DC strain-gauge force transducers and provides digital data input into the
serial port of a standard PC and 16-bit analog outputs. The 4336 generates precision AC sine wave
excitation voltages to power the LVDTs and DC excitation voltages to power the strain-gauge force
bridges. The unit independently compensates each channel's transducer nonlinearities using
its integrated six-point calibration capability. Optional CellView multi-unit graphical user
interface software is available. Electro Standards Laboratories Inc, 36 Western Industrial
Drive, Cranston, RI 02921-3403, http://www.electrostandards.com
Module for current sensing
The Ametes Bus Bar Module (BBM) from
GMW Associates is an ohmically isolated current sensor for DC and low-frequency currents in bus
bars; it offers measurement from about 100 to 5000 A. The BBM uses two high-sensitivity Hall-effect
integrated circuits to sense the magnetic field symmetrically on opposite sides of the bus bar.
This enables effective cancellation of external magnetic fields without magnetic cores or shielding,
which can give rise to magnetic hysteresis and nonlinearity effects. Offset and sensitivity are
factory calibrated to a fixed magnetic sensitivity. The key features of the BBM include voltage
isolation, small size, and immediate recovery from high overload currents without damage. Three
versions of the BBM are conFigured to accommodate various widths and thicknesses of bus bars. GMW
Associates, 955 Industrial Road, San Carlos, CA 94070, http://www.gmw.com
Accelerometer calibration systems
Kistler Instrument has introduced
two accelerometer calibration systems. The model 8804 laboratory vibration-calibration system
is used as a working standard for back-to-back calibration of accelerometers. The model 8002 is
chiefly used as a primary laboratory standard to maintain NIST traceability of a working calibration
standard such as the 8804. Both systems incorporate the company's 5022 frequency-compensated
charge amplifier; they exhibit high stability and repeatability from 10 Hz to 10 kHz over a wide
amplitude range. They are calibrated for a sensitivity of 10 mV/g (g = standard
acceleration of gravity) that is adjustable to a tolerance of ±0.1%.
The system bandwidth is also adjustable to partially correct the resonant peak of the accelerometer
and thus secure more usable bandwidth. Kistler Instrument Corp, 75 John Glenn Drive, Amherst,
NY 14228-2171, http://www.kistler.com
FBG sensor arrays
QPS Photronics is offering large sensor
arrays that incorporate fiber Bragg grating (FBG) technology. Each array can have up to 100 FBGs,
with a total length of fiber stretching up to a distance of 20 km. Through a front-end switch matrix,
16 of the fiber arrays can be connected to form a star network with a total of 1600 sensors. The networks
can be interrogated using time division multiplexing (TDM), a mechanism well suited for ultralarge
sensor network architecture. The FBG sensor array can also serve medium-size wavelength division
multiplexer networks. The company is developing array-packaging technologies that should lead
to attachable strain sensors, temperature and relative humidity sensors, and sensors for bending
and distortion measurements. QPS Photronics Inc, 217 St. Louis Avenue, Pointe Claire, Quebec,
Canada H9R 5L7, http://www.qpscom.com
Flow meters
Hedland Flow Meters' new HTTP series
portable ultrasonic transit-time flow meters clamp onto the outside of a pipepipe sizes
can be accommodated from 1/2 in. and higherand do not contact the internal liquid. The meter
provides instantaneous rate and accumulated flows for efficient fluid measurement. The HTTP
includes bi-directional flow capability to measure forward total, reverse total, and net total.
The user communicates with the flow meter via a PC serial communications port and IR serial adapter,
for the convenience of no interconnection wires; a 4- to 20-mA analog output is also offered. The
company's UltraLink Microsoft Windows software is included for con_1figuration, calibration,
and troubleshooting. Hedland Flow Meters, Division of Racine Federated Inc, 8635 Washington
Avenue, Racine, WI 53406, http://www.hedland.com
Deformable mirror
Boston Micromachines Corp has introduced
the Mini-DM, a high-resolution, MEMS deformable mirror that is ideal for adaptive optics. It is
used to improve resolution in microscopes, telescopes, and ophthalmic instruments. The MEMS
mirror is an advanced wavefront control device that consists of a mirror membrane supported by
an underlying actuator array. Each actuator can be individually deflected electrostatically
to produce the desired pattern of deformation without hysteresis. The active mirror area of the
Mini-DM is deformed by 32 actuators and can reach frame rates of up to 1000 Hz. The mirror is available
in segmented- or continuous-deformable versions and with an actuator stroke of 1.5, 2.5, or 3.5
µm. Boston Micromachines
Corporation, 108 Water Street, Suite 2L, Watertown, MA 02472, http://www.bostonmicromachines.com
Electropneumatic transducer
The 211 series electropneumatic transducers
from Omega Engineering decrease a supply pressure, converting it to regulated output pressure
in direct proportion to an electrical signal. The transducer accepts a wide range of supply pressures,
from 0.2 bar (3 psig) above the maximum output to 6.9 bar (100 psig). An integral pneumatic volume
booster provides high flow capacityup to 12 scfm. Factory calibrated for direct-acting
operation, the 211 series transducers are field reversible. If used in reverse acting mode, they
require recalibration after the polarity of the signal leads is reversed. The IP211 units are current
controlled (4–20 mA); the EP211 units are voltage controlled (1–5 VDC). All models
can be pipe, panel, or bracket mounted. Omega Engineering Inc, One Omega Drive, P.O. Box 4047,
Stamford, CT 06907-0047, http://www.omega.com
Testing of laser systems
CeTaQ Americas has developed machine
capability analysis (MCA) testing for lasers in medical and biomedical device manufacturing.
In the testing, the system measures the width of a laser cut and the beam size and consistency, then
compares the actual result with the programmed pattern and process settings. The test method is
applicable to all types of lasers including UV, both excimer and diode-pumped solid-state. In
laser processing, the laser head is typically stationary and the product is moved under the beam
via high-precision air-bearing stages. MCA testing verifies the x-y accuracy
of those stages and of the motion-control system, which is critical to such processing. The evaluation
methodology incorporates special vision algorithms and highly accurate glass plates and components.
CeTaQ Americas, 27 Executive Drive, Hudson, NH 03051, http://www.cetaq-americas.com
Correction
May 2006, page 65The
Triad Systems Engineering ILS-7000 series of fiber-coupled laser diode systems from RPMC Lasers
features optical output powers ranging from 1 W up to 100 W, with 20 W from a 100-µm-core
fiber at 915 nm and 975 nm.